A within‐subject comparison of changes in core temperature with hypoxia‐induced manipulations of relative exercise intensity
Notice bibliographique
Résumé
Traditionally, relative exercise intensity (i.e., %VO 2max ) has been thought to determine changes in core temperature during exercise in compensable environments; however, recent evidence from our laboratory has suggested otherwise. Using independent group designs, we have demonstrated that to make unbiased comparisons of changes in core temperature, exercise intensities should be set to elicit a fixed metabolic heat production (H prod ) per unit of total body mass (W/kg), irrespective of large differences in %VO 2max (Jay et al. Am J Physiol. 2011) or absolute H prod (Cramer & Jay, J Appl Physiol. 2014). Using a within‐subject design, the present study assessed whether changes in core temperature during exercise at a given H prod in W/kg are altered by differences in %VO 2max , secondary to acute hypoxia exposure (~13% O 2 ) compared to normoxia (21% O 2 ). It was also assessed whether the change in core temperature during exercise at a fixed %VO 2max in hypoxic (HYP) conditions will be similar to normoxia (NORM) despite a 31±8% reduction in hypoxic VO 2max and therefore a much lower H prod . Four participants (1.78±0.04 m, 69.9±5.3 kg, 27±5 y) cycled for 45 min at 34°C, 45% RH in a climate‐controlled chamber. Measurements of esophageal temperature (T es ) and rectal temperature (T re ) were recorded every 5 s, and indirect calorimetry was recorded breath‐by‐breath. Preliminary data indicate that 45‐min ΔT es during exercise at a fixed H prod (NORM: 6.3±0.4 W/kg; HYP: 6.9±0.4 W/kg; P=0.13) were similar between conditions (NORM: 0.52±0.22°C; HYP: 0.47±0.27°C; P=0.61), while ΔT re were also similar (NORM: 0.71±0.26°C; HYP: 0.74±0.27°C; P=0.41), despite large differences in relative exercise intensity (NORM: 40±8%VO 2max ; HYP: 62±8% VO 2max ; P=0.02). However, when a subsequent bout of hypoxic exercise was normalized for %VO 2max (NORM: 40±8%VO 2max ; HYP: 46±4% VO 2max ; P=0.07), ΔT es in the hypoxic condition were lower compared to the normoxic condition (NORM: 0.52±0.22°C; HYP: 0.34±0.25°C; P<0.01) and ΔT re was lower as well (NORM: 0.71±0.26°C; HYP: 0.52±0.30°C; P=0.04) due to a lower H prod (NORM: 6.3±0.4 W/kg; HYP: 5.3±0.6 W/kg; P=0.02). In conclusion, our within‐subject comparison provides further evidence that changes in core temperature are determined by exercise at a fixed H prod in W/kg, despite large differences in relative exercise intensity, and that exercise at a fixed %VO 2max , but different H prod in W/kg, results in different changes in core temperature. Support or Funding Information This project was supported by a Discovery grant from the Natural Sciences and Engineering Research Council (NSERC) of Canada, and also in part by a research grant from the Gatorade Sports Science Institute.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,002 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,001 | 0,001 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,001 |
| Intégrité de la recherche | 0,001 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,003 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».