Measuring Heart Rate Accurately in Patients With Parkinson Disease During Intense Exercise: Usability Study of Fitbit Charge 4
Notice bibliographique
Résumé
BACKGROUND: Parkinson disease (PD) is the second most common neurodegenerative disease, affecting approximately 1% of the world's population. Increasing evidence suggests that aerobic physical exercise can be beneficial in mitigating both motor and nonmotor symptoms of the disease. In a recent pilot study of the role of exercise on PD, we sought to confirm exercise intensity by monitoring heart rate (HR). For this purpose, we asked participants to wear a chest strap HR monitor (Polar Electro Oy) and the Fitbit Charge 4 (Fitbit Inc) wrist-worn HR monitor as a potential proxy due to its convenience. Polar H10 has been shown to provide highly accurate R-R interval measurements. Therefore, we treated it as the gold standard in this study. It has been shown that Fitbit Charge 4 has comparable accuracy to Polar H10 in healthy participants. It has yet to be determined if the Fitbit is as accurate as Polar H10 in patients with PD during rest and exercise. OBJECTIVE: This study aimed to compare Fitbit Charge 4 to Polar H10 for monitoring HR in patients with PD at rest and during an intensive exercise program. METHODS: A total of 596 exercise sessions from 11 (6 male and 5 female) participants were collected simultaneously with both devices. Patients with early-stage PD (Hoehn and Yahr ≤2) were enrolled in a 6-month exercise program designed for patients with PD. They participated in 3 one-hour exercise sessions per week. They wore both Fitbit and Polar H10 during each session. Sessions included rest, warm-up, intense exercise, and cool-down periods. We calculated the bias in the HR of the Fitbit Charge 4 at rest (5 min) and during intense exercise (20 min) by comparing the mean HR during each of the periods to the respective means measured by Polar H10 (HRFitbit - HRPolar). We also measured the sensitivity and specificity of Fitbit Charge 4 to detect average HRs that exceed the threshold for intensive exercise, defined as 70% of an individual's theoretical maximum HR. Different types of correlations between the 2 devices were investigated. RESULTS: The mean bias was 1.68 beats per minute (bpm) at rest and 6.29 bpm during high-intensity exercise, with an overestimation by Fitbit Charge 4 in both conditions. The mean bias of the Fitbit across both rest and intensive exercise periods was 3.98 bpm. The device's sensitivity in identifying high-intensity exercise sessions was 97.14%. The correlation between the 2 devices was nonlinear, suggesting Fitbit's tendency to saturate at high values of HR. CONCLUSIONS: The performance of Fitbit Charge 4 is comparable to Polar H10 for assessing exercise intensity in a cohort of patients with PD (mean bias 3.98 bpm). The device could be considered a reasonable surrogate for more cumbersome chest-worn devices in future studies of clinical cohorts.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,003 | 0,007 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,001 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,001 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».