Differential Breast Microwave Radar Imaging: Diagnostic Performance Evaluation and Comparison to Single-Breast Diagnosis
Notice bibliographique
Résumé
Microwave breast imaging (MBI) has been explored as a breast cancer diagnostic tool, but despite the proliferation of clinical evaluation of MBI systems, challenges remain before the modality is ready for clinical use. Suppression of the dominant skin responses, which obfuscate the interior tissues, is a major challenge. A possible solution to this challenge is differential imaging, rather than single-breast images, where only differences between the left/right breasts are displayed. This work presents the first estimates of diagnostic sensitivity and specificity obtained in MBI using a differential imaging approach. The delay-and-sum (DAS), delay-multiply-and-sum (DMAS), and optimization-based radar reconstruction (ORR) algorithms were used. Only the ORR method achieved better-than-random diagnostic performance when the tumour-detection criteria were defined using the signal-to-clutter ratio and localization error. This work also identified the potential of using the maximum image intensity as a diagnostic criterion. When this maximum-response-based metric was used, the diagnostic performance of all reconstruction methods improved. The ORR algorithm was the best performing method and achieved an area under the curve of the receiver operating characteristic curve of 84.6%.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».