EVALUATING FEASIBILITY AND DURABILITY OF THE AERO PROSTHETIC LINER IN TRANSTIBIAL PROSTHETIC USERS

2023· article· en· W4390222825 sur OpenAlexvenueaboutno aff
Yusuke Miyata, Kazuhiko Sasaki, Gary Guerra, Woratee Dacharux, Pilipda Chaiwan

Notice bibliographique

RevueCanadian Prosthetics & Orthotics Journal · 2023
Typearticle
Langueen
DomaineEngineering
ThématiqueProsthetics and Rehabilitation Robotics
Établissements canadiensnon disponible
Organismes subventionnairesFaculty of Medicine Siriraj Hospital, Mahidol UniversityMahidol University
Mots-clésProsthesisDurabilityMedicinePhysical therapySurgeryMaterials scienceComposite material

Résumé

récupéré en direct d'OpenAlex

BACKGROUND: The choice of prosthetic socket interface material significantly affects user comfort and satisfaction. The Affordable Ethylene-Vinyl Acetate Roll-On (AERO) liner was created with the aim of improving functionality and streamlining the wearing process for users. OBJECTIVE: The purpose of this study was to comprehensively assess user satisfaction, comfort, and durability of the AERO liner and compare it with the common soft Pe-Lite liner. METHODOLOGY: Fourteen individuals with transtibial amputation participated in this three-month randomized crossover trial study. The Prosthesis Evaluation Questionnaire (PEQ), Expanded Socket Comfort Score (ESCS), and liner thickness measurements were used to comprehensively compare the AERO and Pe-Lite liner. FINDINGS: The AERO liner demonstrated notable improvements in prosthetic comfort and functionality over Pe-Lite liner. After three months use, there was a significant reduction in reported frustration with the AERO liner (p=0.023, r=0.604) in the PEQ subscale. Specific aspects, such as walking with the prosthesis (p=0.030, r=0.601) and odor perception (p=0.024, d=0.579), favored the use of the AERO liner. The expanded socket comfort score (ESCS) revealed significant superiority for the AERO liner “at best” (p=0.04) and “on average” (p=0.02) after one and three months, respectively. Liner thickness analysis showed significant reductions at the mid-patellar tendon location for the AERO liner at one (0.57±0.48) and three months (0.90±0.69, p=0.01) and in the posterior region after three months (0.63±0.64, p=0.05). CONCLUSION: Our study highlights the potential advantages of the AERO liner in enhancing comfort and satisfaction. Yet, durability and thinning of the liner when compared to Pe-Lite may be a concern which may eventually affect socket fit. These findings contribute to ongoing efforts to optimize prosthetic interventions and improve the quality of life of individuals with lower limb prosthesis in resource-limited environments. Layman's Abstract Comfort and satisfaction are essential for people using prosthetics. The socket interface material, which encompasses the limb, is crucial for comfort and suspension of the prosthesis on the limb. In resource-limited environments, people mainly use an interface material called Pe-Lite in their prosthetic sockets. However, there is an ongoing debate regarding its comfort and suitability for the residual limb. We aimed to evaluate an alternative material to determine if it was more comfortable and functional than Pe-Lite for these individuals. We invited fourteen people with transtibial amputations to participate in this study. They used a traditional prosthetic design and were provided both Pe-Lite and AERO liners. We asked them about their experiences and measured the various aspects of their treatment. The results were promising. People who used the AERO liner reported much less frustration after three months. They felt an improvement in walking, and they didn't have odor problems expressed when using Pe-Lite. The AERO liner was more comfortable when using the prosthesis. Although the AERO liner compressed more in certain areas compared to the Pe-Lite liner, it remained usable after three months. However, reduce the liner thickness compared to Pe-Lite may be a concern and could affect the socket fit. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/41865/32282 How To Cite: Miyata Y, Sasaki K, Guerra G, Dacharux W, Chaiwan P. Evaluating feasibility and durability of the AERO prosthetic liner in transtibial prosthetic users. Canadian Prosthetics & Orthotics Journal. 2023; Volume 6, Issue 1, No.5. https://doi.org/10.33137/cpoj.v6i1.41865 Corresponding Author: Kazuhiko Sasaki, Sirindhorn School of Prosthetics and Orthotics, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand.E-Mail: kazuhiko.sas@mahidol.eduORCID ID: https://orcid.org/0000-0002-1778-6308

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,002
score de la tête « metaresearch » (Gemma)0,001
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesMéta-épidémiologie (sens strict)
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Observationnel · Signal consensuel: Observationnel
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,077
Score d'incertitude au seuil1,000

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0020,001
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0000,000
Bibliométrie0,0000,001
Études des sciences et des technologies0,0000,001
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,001
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,038
Tête enseignante GPT0,282
Écart entre enseignants0,244 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Devis d'étudeObservationnel
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations0
Publié2023
Routes d'admission2
Résumé présentoui

Explorer davantage

Même revueCanadian Prosthetics & Orthotics JournalMême sujetProsthetics and Rehabilitation RoboticsTravaux en français237 207