Prolonged mHealth-Based Arrhythmia Monitoring in Patients With Hypertrophic Cardiomyopathy (HCM-PATCH): Protocol for a Single-Center Cohort Study
Notice bibliographique
Résumé
BACKGROUND: Patients with hypertrophic cardiomyopathy (HCM) are at increased risk of sudden cardiac death (SCD) due to ventricular arrhythmias and other arrhythmias. Screening for arrhythmias is mandatory to assess the individual SCD risk, but long-term electrocardiography (ECG) is rarely performed in routine clinical practice. Intensified monitoring may increase the detection rate of ventricular arrhythmias and identify more patients with an increased SCD risk who are potential candidates for the primary prophylactic implantation of an implantable cardioverter-defibrillator. To date, reliable data on the clinical benefit of prolonged arrhythmia monitoring in patients with HCM are rare. OBJECTIVE: This prospective study aims to measure the prevalence of ventricular arrhythmias in patients with HCM observed by mobile health (mHealth)-based continuous rhythm monitoring over 14 days compared to standard practice (a 24- and 48-h long-term ECG). The frequency of ventricular arrhythmias in this 14-day period is compared with the frequency in the first 24 or 48 hours for the same patient (intraindividual comparison). METHODS: Following the sample size calculation, 34 patients with a low or intermediate risk for SCD, assessed by the HCM Risk-SCD calculator, will need to be recruited in this single-center cohort study between June 2023 and February 2024. All patients will receive an ECG patch that records their heart activity over 14 days. In addition, cardiac magnetic resonance imaging and genetic testing data will be integrated into risk stratification. All patients will be asked to complete questionnaires about their symptoms; previous therapy; family history; and, at the end of the study, their experience with the ECG patch-based monitoring. RESULTS: The Hypertrophic Cardiomyopathy: Clinical Impact of a Prolonged mHealth-Based Arrhythmia Monitoring by Single-Channel ECG (HCM-PATCH) study investigates the prevalence of nonsustained ventricular tachycardia (ie, ≥3 consecutive ventricular beats at a rate of 120 beats per minute, lasting for <30 seconds) in low- to intermediate-risk patients with HCM (according to the HCM Risk-SCD calculator) with additional mHealth-based prolonged rhythm monitoring. The study was funded by third-party funding from the Department of Cardiology and Intensive Care Medicine, University Hospital Ostwestfalen-Lippe of Bielefeld University in June 2023 and approved by the institutional review board in May 2023. Data collection began in June 2023, and we plan to end the study in February 2024. Of the 34 patients, 26 have been recruited. Data analysis has not yet taken place. Publication of the results is planned for the fall of 2024. CONCLUSIONS: Prolonged mHealth-based rhythm monitoring could lead to differences in the prevalence of arrhythmias compared to 24- and 48-hour long-term ECGs. This may lead to improved identification of patients at high risk and trigger therapeutic interventions that may provide better protection from SCD or atrial fibrillation-related complications such as embolic stroke. TRIAL REGISTRATION: Deutsches Register Klinischer Studien DRKS00032144; https://tinyurl.com/498bkrx8. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/52035.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,018 | 0,012 |
| Méta-épidémiologie (sens strict) | 0,003 | 0,002 |
| Méta-épidémiologie (sens large) | 0,004 | 0,003 |
| Bibliométrie | 0,002 | 0,002 |
| Études des sciences et des technologies | 0,003 | 0,002 |
| Communication savante | 0,002 | 0,002 |
| Science ouverte | 0,002 | 0,002 |
| Intégrité de la recherche | 0,003 | 0,002 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,017 | 0,006 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».