MétaCan
Menu
Retour à la cohorte
Enregistrement W4391638853 · doi:10.1149/ma2023-02371787mtgabs

Interactions between Catalyst Layer Degradation and Liquid Water Distribution in Polymer Electrolyte Fuel Cells

2023· article· en· W4391638853 sur OpenAlexaffabout
Fabusuyi Akindele Aroge, Jonathan Halter, Olivia C. Lowe, John A MacDonald, Francesco P. Orfino, Monica Dutta, Erik Kjeang

Notice bibliographique

RevueECS Meeting Abstracts · 2023
Typearticle
Langueen
DomaineEngineering
ThématiqueFuel Cells and Related Materials
Établissements canadiensSimon Fraser University
Organismes subventionnairesnon disponible
Mots-clésElectrolyteDegradation (telecommunications)PolymerLayer (electronics)CatalysisChemical engineeringLiquid waterFuel cellsMaterials scienceChemistryComposite materialOrganic chemistryThermodynamicsEngineeringElectrodeElectrical engineeringPhysics

Résumé

récupéré en direct d'OpenAlex

Managing liquid water distribution in PEFCs is critical to desirable high power density operation and cell durability [1–3]. Degradation modes such as carbon corrosion in the cathode catalyst layer (CCL) are believed to depend on local humidification [2,4], while the distribution of liquid water may also be influenced by performance drop associated with such degradation [3]. Although some studies have shown the influence of carbon corrosion on liquid water distribution [2,3], the possible reverse effect of liquid water distribution on the CCL degradation requires further investigation. The objective of the present work is to establish a deeper understanding of the cause-and-effect interactions between CCL degradation and liquid water distribution. This is achieved experimentally by carrying out voltage-cycling accelerated stress tests (ASTs) on fuel cells which differ only in the constituent gas diffusion layers (GDLs); namely, SGL 22 BB and a proprietary Avcarb. Three-dimensional X-ray microscopy is used to observe both degradation effects and liquid water distribution at different stages of the ASTs. A relatively rapid operando two-dimensional visualization technique [5] was also used to investigate the differences in liquid water distribution between the two GDLs. The fuel cells imaged are analyzed and exhibit different liquid water distributions, whereby the Avcarb exhibits a higher liquid water condensation close to the CCL, compared to the SGL. Supported by model results, this difference in liquid water distribution is shown to be attributable to the different transport properties of the GDLs. The degradation results, such as the CCL thickness (Fig. 1) show that the Avcarb cell experiences a faster CCL degradation than the SGL cell. Furthermore, the Avcarb liquid water distribution is seen to change with increasing AST cycles in a manner indicating higher vapour phase removal. These results provide insights for GDL design consideration, showing that GDL transport properties may influence liquid water distribution at the electrode with important implications for CCL durability. Acknowledgement Funding for this research was provided by the Natural Sciences and Engineering Research Council of Canada, Ballard Power Systems, Canada Foundation for Innovation, British Columbia Knowledge Development Fund, and Canada Research Chairs. References [1] F. Nandjou, J.-P. Poirot-Crouvezier, M. Chandesris, J.-F. Blachot, C. Bonnaud, and Y. Bultel, “Impact of heat and water management on proton exchange membrane fuel cells degradation in automotive application,” Journal of Power Sources, vol. 326, pp. 182–192, 2016. [2] J. D. Fairweather, D. Spernjak, A. Z. Weber, D. Harvey, S. Wessel, D. S. Hussey, D. L. Jacobson, K. Artyushkova, R. Mukundan, and R. L. Borup, “Effects of cathode corrosion on through-plane water transport in proton exchange membrane fuel cells,” Journal of The Electrochemical Society, vol. 160, no. 9, p. F980, 2013. [3] R. T. White, S. H. Eberhardt, Y. Singh, T. Haddow, M. Dutta, F. P. Orfino, and E. Kjeang, “Four-dimensional joint visualization of electrode degradation and liquid water distribution inside operating polymer electrolyte fuel cells,” Scientific reports, vol. 9, no. 1, p. 1843, 2019. [4] T. Mittermeier, A. Weiß, F. Hasché, and H. A. Gasteiger, “Pem fuel cell start-up/shut-down losses vs relative humidity: the impact of water in the electrode layer on carbon corrosion,” Journal of The Electrochemical Society, vol. 165, no. 16, p. F1349, 2018. [5] F. Aroge, B. Parimalam, J. MacDonald, F. Orfino, M. Dutta, and E. Kjeang, “Analysing operando 2d x-ray transmission images for liquid water distribution in polymer electrolyte fuel cells,” Journal of Power Sources, vol. 564, p. 232820, 2023. Figure 1

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,000
score de la tête « metaresearch » (Gemma)0,000
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Expérimental (laboratoire) · Signal consensuel: Expérimental (laboratoire)
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,029
Score d'incertitude au seuil0,472

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0000,000
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0000,000
Bibliométrie0,0000,000
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,011
Tête enseignante GPT0,220
Écart entre enseignants0,209 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeExpérimental (laboratoire)
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations0
Publié2023
Routes d'admission2
Résumé présentoui

Explorer davantage

Même revueECS Meeting AbstractsMême sujetFuel Cells and Related MaterialsTravaux en français237 207