Performance of Fourier-based activation function in physics-informed neural networks for patient-specific cardiovascular flows
Pourquoi ce travail est dans la base
Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.
Notice bibliographique
Résumé
BACKGROUND AND OBJECTIVES: Physics-informed neural networks (PINNs) can be used to inversely model complex physical systems by encoding the governing partial differential equations and training data into the neural network. However, neural networks are known to be biased towards learning less complex functions, called spectral bias. This has important implications in modeling cardiovascular flows, where spatial frequencies can vary substantially across anatomies and pathologies (e.g., aneurysms or stenoses). Recent evidence suggests that Fourier-based activation functions have desirable properties, and can potentially reduce spectral bias; however, the performance and adequacy of such Fourier activation functions have not yet been evaluated in patient-specific cardiovascular flow applications. METHODS: The performance of sine activation function was evaluated against tanh and swish activation functions in a 1D advection-diffusion problem, an eccentric 2D stenosis model (Re=5000), and a patient-specific 3D aortic model (Re=823) under pulsatile flow conditions. CFD simulations were performed at high spatio-temporal resolution and data points were extracted for training the neural network. The number of training data points were normalized by L/D. The performance of the PINNs framework was evaluated with increasing number of training data points and across all three activation functions. RESULTS: Our results demonstrate that sine activation function presents desirable characteristics, such as monotonic reduction in errors, relatively faster convergence, and accurate eigen spectra at higher modes, compared to tanh and swish activation functions. Interestingly, for all activation functions, the domain-averaged errors tended to asymptote at ≈15-20% despite substantial increase in training point density. For 2D eccentric stenosis, errors asymptoted at a sensor point density of 40L/D. For 3D patient-specific aorta, this asymptote was achieved at 180L/D for all three activation functions with an error of ≈15% although sine activation function demonstrated relatively faster convergence. CONCLUSIONS: We have demonstrated that Fourier-based activation functions have higher performance in terms of accuracy and convergence properties for cardiovascular flow applications; however, inherent challenges of neural networks (e.g., spectral bias) can limit the accuracy to ≈15% under physiological, 3D patient-specific blood flow conditions.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle