HIGH POWER MAGNETOSTRICTIVE TONPILZ TRANSDUCERS
Notice bibliographique
Résumé
Due to the continuing interest of the French Navy (DCN & DRET), signi cant improvements have been made to magnetostrictive transducers to produce low-frequency, high-power sonar sources. Much progress has been made in the eld of Tonpilz transducers as a result of these improvements. The previous Quadripode transducer was built in two versions, Quadripode I and II. They had acoustic power of 1.0 and 1.6 kW, respectively. Next, an attempt to design a third version of the Quadripode led to a new Tonpilz transducer called the Tripode. Its purpose is to reach an acoustic power of at least 3 kW. It bene ts from magnetic circuit design results and from the giant dynamic strain capability of Terfenol-D (Peak-to-Peak strain higher than 2400ppm) discovered in 90-91. In this paper, the modelling results are reminded, and the results obtained from the rst series of inwater measurements of the Tripode are analyzed. These results tend to con rm expectations. of nding shading coef cients for any arbitrary array geometry and a given set of beampattern requirements.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,037 | 0,002 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; les deux têtes enseignantes s’accordent sur ce qui est montré ici.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».