In reply to Masjedi et al
Notice bibliographique
Résumé
We thank Dr. Masjedi for taking the time to review our paper, Measurement of neutron yield for a medical linear accelerator below 10 MV,1 and to provide thoughtful commentary on our experimental methods. The motivation for this work was to address the lack of experimental data in the literature regarding neutron doses from medical linear accelerators at intermediate energies, between 6 and 10 MV. Medical linear accelerators typically use a 5.5 MeV electron beam to produce a 6 MV beam. Since this is below the activation threshold for most common elements (see Figure 5 in our paper1), and since medical linear accelerator OEMs do not include other energies below 10 MV in commercially available systems, there was not any data available in the literature at any energy below 10 MV for a commercially available medical linear accelerator. We believe this to be an important area where more data will benefit the radiotherapy community since it may enable and help to justify technique development for volume-based radiotherapy treatments at intermediate energies. So, the primary purpose of the experiment we reported on was simply to provide first estimates of photoneutron yields at an intermediate energy of 8 MV. We acknowledge that the experimental methodology can be improved, and we hope that other investigators will undertake further experiments to increase the availability in the open literature of photoneutron yield estimates in this energy range. Regarding the measurements with jaws open and closed, we reviewed our original data books, and confirm that the values reported in Table S1 are what was recorded in our logbooks. However, we did not rely on this data for any of the analysis. It appears, as Dr. Masjedi suggests, to be possibly related to photon contamination from the open field, and we thank Dr. Masjedi for bringing this to our attention. The results presented in Table S1 are the complete set of measurements that we obtained and are presented with the paper in the case where they may have value to a reader. We only relied on the data presented in Table 3 for our analysis, which were all taken with jaws closed, where the issues with dose pile up should not be a concern. We also agree that the presence of the flattening filter in the experiment was not ideal and adds uncertainty to the result. This was acknowledged in Section 4.6 of the paper, paragraph 1. While we did not discuss this directly in the write up of the paper, we admit that we had not fully anticipated the effects of the flattening filter on the experimental results until we were conducting the experiment. By this time, we were not able to respond ideally since the timeline of the experiment was largely dictated by the machine replacement schedule, which was strictly controlled. We hope to be able to repeat these measurements in the future, and we will have a better plan for understanding the effects of the flattening filter. We also encourage other investigators to repeat these experiments under better controlled conditions, to improve the accuracy of the neutron dose associated with intermediate energy photon beams. In doing these experiments, a significant and limiting factor was the timeline dictated by the linear accelerator replacement cycle. Ideally, we would have had time to collect data, and adapt our experimental methods accordingly. As well, since our clinic is not equipped with the ideal neutron detecting devices, we spent some time optimizing the measurements to see what conditions would provide optimal data. So, for this reason, we tried several room configurations, beam directions, jaw positions, and even measurement points in the maze of the linear accelerator bunker. The data presented in Table S1 is meant to provide as much transparency over our experimental methodology, and in this spirit, we welcome and encourage commentary on our methodology as we believe this will instill confidence in the results. In general, we appreciate the comments from Dr. Masjedi, and agree with the sentiment of the comments, which was that the experimental methodology of the neutron measurements can be improved. We did attempt to place uncertainties on the measurements by incorporating uncertainty in the neutron spectrum into our final results, which are larger than the 25% variation in data discussed by the reader. The difficulty with these types of experiments is that they are done in a non-ideal environment (a hospital, with limited access to neutron detection equipment), and under strict time constraints. This is why, in Section 4.4, where we present the principal results of our experiment, we quote the neutron source strength from an electron beam at 8 MeV to be “about 1 order of magnitude less than 10 MV photon beam”. By using the term order of magnitude, our intent was to convey the uncertainty in our result. However, the comments brought up in Dr. Masjedi's letter are valid, and we agree that a specific error analysis is a better approach to explain the uncertainty in our experimental results. Finally, we note that for other reports of photoneutron yield, significant variation in results exist depending on the type of medical linear accelerator used in the study (see for instance, Table 2 of Naseri and Mesbahi,2 and Figure 4 of Carlone and colleagues1). This is presumably due to the inherent difficulties of conducting this type of experiment in a hospital environment, and the variation in composition and construction of different medical linear accelerators. We encourage potential investigators who may be contemplating the types of measurements we describe in our paper to utilize the most accurate experimental methodology, as suggested by Dr. Masjedi, to reduce uncertainties in this general area, and improve the quality of data available.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,008 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,001 |
| Intégrité de la recherche | 0,000 | 0,004 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,001 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».