MétaCan
Menu
← Retour à la cohorte
Enregistrement W4394822991 · doi:10.22541/au.171322254.42908531/v1

Advancing Transcatheter Valve Replacement for Severe Aortic Regurgitation: Innovations in Devices and Multi-Modality Imaging

2024· preprint· en· W4394822991 sur OpenAlexaffabout
Julien Dreyfus, David Messika–Zeitoun

Notice bibliographique

Revuenon disponible
Typepreprint
Langueen
DomaineMedicine
ThématiqueCardiac Valve Diseases and Treatments
Établissements canadiensUniversity of Ottawa
Organismes subventionnairesnon disponible
Mots-clésMedicineRegurgitation (circulation)CardiologyInternal medicineValve replacementAortic valveAortic valve replacementFluoroscopySurgeryStenosis

Résumé

récupéré en direct d'OpenAlex

Advancing Transcatheter Valve Replacement for Severe Aortic Regurgitation: Innovations in Devices and Multi-Modality ImagingJulien Dreyfus, MD, PhD1; David Messika-Zeitoun, MD, PhD21: Cardiology Department, Centre Cardiologique du Nord, 32-36 rue des moulins gémeaux, 93200 Saint-Denis, France2: Division of Cardiology, University of Ottawa Heart Institute, 40 Ruskin Street, Ottawa, Ontario, CanadaWord Count : 912 wordsAddress for correspondence :Julien Dreyfus, Department of Cardiology, Centre Cardiologique du Nord, Saint-Denis, France. Tel: +33149334803, Fax: +33149334143, E-mail: dreyfusjulien@yahoo.frFor patients with severe symptomatic aortic regurgitation (AR) who are deemed at high surgical risk, off-label use of transcatheter aortic valve replacement (TAVR) is increasingly performed. However, the rate of complications is high in this subset, including migration, paravalvular regurgitation, pacemaker implantation, stroke, bleeding, vascular complication, acute renal failure, surgical conversion and mortality.(1)In this issue of Echocardiography , Hu et al (ref) present their findings on 70 patients (56% of males, mean age=74±8 years) with severe symptomatic AR (all in NYHA functional class III or IV) on native or bioprosthetic valves who underwent a TAVR using the Vita-Flow valves (Microport), a novel self-expanding valve (Figure). The population was divided into two groups: group A consisted of 40 patients with aortic root dilatation or valve prolapse and no valvular calcifications, while group B comprised 30 patients with aortic valve degeneration and/or mild senile calcifications (Agatston score ranging from 0 to 100). All interventions were performed under general anesthesia, with procedural guidance provided by both fluoroscopy and real-time three-dimensional echocardiography. A comprehensive pre-procedural assessment of the anatomy was conducted using both transesophageal echocardiography (TEE) and computed tomography (MSCT) and dedicated software. The study focuses on the utility of echocardiography in the pre-procedural screening, intra-procedural monitoring, and 30-day post-procedural follow-up, while also identifying potential predictors for post-procedural complications.The main results from the study can be summarized as follow:Multimodality imaging analysis demonstrated significant concordance between TEE and MSCT especially in the assessment of the annulus and aorta dimensions, as well as left and right coronary artery height, enabling accurate device sizing.The procedural success rate was high (96%) and there were no deaths at 30 days.Multiple underlying mechanisms of AR were successfully treated.Mild peri-valvular leakage was observed in 16% of cases but no moderate or greater peri-valvular leakage was reported.Incidence of significant complications was low, with 3% experiencing iliac artery dissection, 4% encountering stroke, and 3% developing acute renal insufficiency within 30 days post-procedure. No migration was reported.A noteworthy 22% of patients required new pacemaker implantation due to complete atrioventricular block, with a median implantation time of 6 days with right bundle branch block as the only independent predictor.Procedural success correlated with a positive left ventricular and atrial remodeling at 30 days (reductions in left atrial and left ventricular diameters, and improvement of the left ventricular ejection fraction).The main limitations of this study include its retrospective single-center design, small sample size (although relatively large for a single center), mix of TAVR on native valves and valve-in-valve procedures, and a short follow-up period.A significant proportion of patients with surgical indications for severe AR are not referred, often due to high surgical risk or comorbidities(2,3). Transcatheter treatment of AR is currently on the rise but is much more challenging than for aortic stenosis, notably due to the absence of calcifications.TAVR is currently mostly performed using prostheses developed for aortic stenosis. A recent multicenter registry (PANTHEON) including 201 patients treated with commercially available devices (self-expandable and balloon expendable valves developed for AS) showed that with improvements in TAVR devices, in experienced centers and in selected patients, satisfactory outcomes can be achieved in a majority of patients, but that complications rates remained high (12% of embolization or migration at 1 month and 10% of moderate or greater residual leakage), regardless of prosthesis type. Critically, these complications were associated with high mortality or hospitalization for heart failure rates at 1 year (approximately 25%). Rates of permanent pacemaker implantation were also high (approximately 22%), often associated with device oversizing.(1)Several devices designed for the management of AR are currently available or under evaluation. Presently, the JenaValve Trilogy system (JenaValve Technology) is the only dedicated device to have received Conformité Européenne (CE) mark approval for the transcatheter treatment of patients with AR. A recent multicenter registry, comprising 58 consecutive patients from 6 centers across Germany, demonstrated excellent outcomes with a 98% implantation success rate, the absence of moderate or severe paravalvular regurgitation, a 30-day mortality rate of 1.7%, and a 19.6% rate of new permanent pacemaker implantation.(4) The Jena-Valve ALIGN-AR Pivotal Trial (NCT04415047) included 177 patients with 91% of procedures performed under general anesthesia. The trial yielded a procedural success rate of 95%, with 3% of patients necessitating subsequent surgery. Only 0.6% experienced moderate or severe paravalvular regurgitation, and 30-day mortality rate was 2.2%. Additionally, 24% of patients received new pacemaker implantation, a rate that tended to decrease with experience, particularly with refined strategies for device sizing and positioning.The J-Valve (JC Medical), specifically designed for the treatment of patients with AR, is another alternative. A recent study including 27 patients for compassionate use found a procedural success rate of 81% overall and 100% in the last 15 cases, with no patient having residual AR of moderate or greater degree at 30 days and a 13% rate of new pacemaker implantation.(5)In conclusion, there is a genuine enthusiasm for transcatheter AR management, driven by both industry innovation and clinical demand. Dedicated devices seem to perform better than devices commercially used for aortic stenosis, but pacemaker implantation rate remains high. Multimodal imaging plays a pivotal role in patient and device selection, procedural guidance, and follow-up. Although echocardiography seems accurate, as for aortic stenosis, MSCT will remain the method of choice for pre-intervention procedural planning. As the landscape rapidly evolves, refining patient selection, procedural techniques, and postprocedural care will be paramount to ensuring optimal outcomes in this challenging patient population.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction machine sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.

score de la tête « metaresearch » (Codex)0,002
score de la tête « metaresearch » (Gemma)0,003
Version: metacan-v3-hybrid-931329e0061cStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Sans objet · Signal consensuel: aucune
GenreSignal candidat: Autre · Signal consensuel: aucune
Score de désaccord entre enseignants0,002
Score d'incertitude au seuil0,009

Scores du classifieur distillé par catégorie (deux têtes)

CatégorieCodexGemma
Métarecherche0,0020,003
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0010,000
Bibliométrie0,0020,001
Études des sciences et des technologies0,0000,001
Communication savante0,0020,002
Science ouverte0,0000,000
Intégrité de la recherche0,0010,002
Charge utile insuffisante (le modèle a refusé de juger)0,0020,001

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,022
Tête enseignante GPT0,379
Écart entre enseignants0,357 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeSans objet
Domainenon disponible
GenreAutre

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations0
Publié2024
Routes d'admission2
Résumé présentoui

Explorer davantage

Même sujetCardiac Valve Diseases and Treatments→Travaux en français237 207→