Excellent survival of two anatomically adapted hydroxyapatite coated cementless Total Hip Arthroplasties. A mean follow-up of 11.3 years
Notice bibliographique
Résumé
There are many different types of cementless anatomically adapted Total Hip Arthroplasties (THAs) on the market, the Anatomic Benoist Gerard (ABG) I and II are such types of cementless THAs. In this retrospective single-centre study we evaluated the overall survival with revision for any reason and aseptic loosening as endpoint at more than 11 years follow-up. Between 2000 and 2004, 244 cementless THAs were performed in 230 patients in a primary care hospital. At a mean of 11.3 years follow-up (range 9.8 - 12.8 years) clinical examination, plain radiography and Patient Reported Outcome Measures (PROMs) were obtained and analysed. The PROMs consisted of the Oxford Hip Score (OHS) and the Western Ontario and McMaster University Index (WOMAC). At a mean of 11.3 years follow-up 32 patients (13.1%) had died of unrelated causes. Of the remaining cohort all 198 patients (212 THAs) have been reached for evaluation. There were no patients considered as lost to follow-up. At a mean of 11.3 years 11 patients (11 THAs) have had a revision of either the femoral implant or acetabular component resulting in an overall survival of 95.5%. There was no statistically significant difference (p=0.564) in survival between the ABG I and II THAs. Radiographic there were no changes between the ABG I and II last follow up. The ABG II performed statistically significant better in PROMs. We concluded that both anatomically adapted hydroxyapatite coated cementless THAs show excellent survival at more than 11 years follow-up.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,001 |
| Bibliométrie | 0,000 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,002 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».