How Does Radiographic Acetabular Morphology Change Between the Supine and Standing Positions in Asymptomatic Volunteers?
Notice bibliographique
Résumé
BACKGROUND: The radiographic appearance of the acetabulum differs between the supine and standing positions in patients with hip conditions. The pelvis undergoes a change in tilt when transitioning between positions, resulting in variations in version and acetabular coverage. However, the extent of these variations in well-functioning volunteers without compensatory patterns caused by pain is unknown. QUESTIONS/PURPOSES: We performed this study to (1) quantify differences in radiographic acetabular measurements when transitioning between supine and standing among asymptomatic, well-functioning volunteers; (2) assess differences in pelvic tilt between positions; and (3) test whether individual anatomic parameters are associated with the change in tilt. METHODS: This was a prospective, single-center study performed at an academic referral center. One hundred volunteers (students, staff, and patients with upper limb injuries) with well-functioning hips (Oxford hip score ≥ 45) were invited to participate. A total of 45% (45) of them were female, their mean age was 37 ± 14 years, and their mean BMI was 25 ± 2 kg/m 2 . Supine and standing AP pelvic radiographs were analyzed to determine numerous acetabular parameters including the lateral center-edge angle (LCEA), acetabular index (AI), anterior wall index (AWI), posterior wall index (PWI), crossover sign (COS), crossover ratio (COR), posterior wall sign (PWS), ischial spine sign (ISS), and femoroepiphyseal acetabular roof index (FEAR), as well as pelvic parameters including the sacrofemoral-pubic angle (SFP). Spinopelvic parameters were measured from lateral standing spinopelvic radiographs. Radiographic measurements were performed by one hip preservation research fellow and a fellowship-trained staff surgeon. Differences in parameters were determined, and correlations between postural differences and morphological parameters were tested. Clinically important differences were defined as a difference greater than 3° for acetabular angle measurements and 0.03 for acetabular ratio measurements, based on previous studies. RESULTS: Lateral coverage angles did not show a clinically important difference between positions. AWI decreased when standing (0.47 ± 0.13 versus 0.41 ± 0.14; p < 0.001), whereas acetabular retroversion signs were more pronounced when supine (COS: 34% [34 of 100], PWS: 68% [68 of 100], and ISS: 34% [34 of 100] versus COS: 19% [19 of 100], PWS: 38% [38 of 100], and ISS: 14% [14 of 100]; all p values < 0.05). Pelvic tilt increased by a mean of 4° ± 4° when standing, but the range of change was from -15° to 7°. The change in AWI (ρ = 0.47; p < 0.001), PWI (ρ = -0.45; p < 0.001), and COR (ρ = 0.52; p < 0.001) between positions correlated with ΔSFP. Volunteers with spinal imbalance (pelvic incidence lumbar lordosis > 10°) demonstrated greater change in pelvic tilt (ΔSFP) (-7° ± 3° versus -4° ± 4°; p = 0.02) and a greater reduction in AWI (by 10%). These volunteers demonstrated reduced standing lumbar lordosis angles (45° ± 11° versus 61° ± 10°; p = 0.001). CONCLUSION: Acetabular version increases from supine to standing because of an increase in pelvic tilt. The change in pelvic tilt between positions exhibited substantial variability. Individuals with reduced lumbar lordosis for a given pelvic incidence value demonstrated greater pelvic mobility. No features on supine radiographs were associated with the change in tilt. CLINICAL RELEVANCE: Performing standing radiographs in addition to supine views can help identify aberrant physiologic patterns in patients with diagnostic dilemmas and might thus help with management. Normative data of pelvic tilt change can help clinicians identify patients who demonstrate excessive change in tilt that contributes to abnormal hip pathomechanics.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,003 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,001 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,001 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,001 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».