P ressure-volume (PV) loops visually display the relationship between left ventricular pressure and volume across the cardiac cycle.Aspects of ventricular function and cardiac mechanics that are not readily available by other means, such as stroke work and contractility, can be quantified using PV loop analysis.1 These metrics are clinically relevant in the growing population of patients with heart failure, both as a tool to improve characterization of cardiac function in clinical practice and as a potential surrogate end point in clinical trials. 2 However, a major barrier to routine clinical implementation is that PV loop measurements have historically required invasive assessment of left ventricular pressures using catheterization.Such measurement involves placement of a PV conductance transducer with tip in the left ventricular apex and proximal end in the aortic root.This allows for simultaneous recording of pressure and volume.However, these invasive measurements are costly and time-consuming, require specific technical expertise, and have inherent associated procedural risks.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,008 | 0,055 |
| Méta-épidémiologie (sens strict) | 0,003 | 0,001 |
| Méta-épidémiologie (sens large) | 0,004 | 0,002 |
| Bibliométrie | 0,003 | 0,001 |
| Études des sciences et des technologies | 0,001 | 0,002 |
| Communication savante | 0,006 | 0,002 |
| Science ouverte | 0,003 | 0,001 |
| Intégrité de la recherche | 0,013 | 0,019 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,018 | 0,009 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».