Pressure regulation of L-type Ca<sup>2+</sup> channels and its role in myogenic response
Notice bibliographique
Résumé
L-type calcium (Ca 2+ ) channels hold a pivotal position in governing intracellular Ca 2+ concentration within smooth muscle and the establishment of myogenic tone. Their primary regulatory mechanism has historically been linked to voltage. Nevertheless, it remains a subject of inquiry whether voltage represents the exclusive modulator or whether these channels also exhibit mechanosensitivity. This study seeks to elucidate the influence of pressure stimuli on L-type Ca 2+ channels in the resistance arteries of rodents (rats and mice). The investigative approach spans from the scrutiny of individual smooth muscle cells employing methodologies such as whole-cell and cell-attached patch-clamp electrophysiology, immunohistochemistry, proximity ligation assay, and super-resolution microscopy to the evaluation of intact arteries utilizing pressure myography. The findings obtained through whole-cell patch-clamp electrophysiology unveil a notable augmentation in L-type Ca 2+ current in response to pressure stimuli. Subsequent scrutiny at the level of single-channel activity discloses that this augmentation is ascribed to an enhancement in functional coupling. Further inquiry reveals that the intensified functional coupling in response to pressure is contingent upon two principal factors: 1) the facilitation of cooperative gating mediated by protein kinase C (PKC), and 2) the traffcking of subunits to caveolae. Notably, functional experiments, involving depolarization elicited through the application of 30 mM KCl, underscore that arterial tone and cytosolic Ca 2+ concentration responses are markedly more pronounced when the arteries are subjected to a pressure of 80 mmHg, as opposed to 20 mmHg. The culmination of these observations from both patch-clamp experiments and functional investigations supports the assertion that L-type Ca 2+ channels are indeed amenable to mechanosensory influences, in addition to their well-documented voltage-dependent behavior. In summation, this investigation underscores that the regulatory landscape of L-type Ca 2+ channels transcends the confines of voltage control, emphasizing the significance of considering pressure sensitivity in both physiological and pathological contexts. Ongoing research endeavors aim to delineate with precision the signaling complexes within vascular smooth muscle that respond to mechanical forces. Supported by the Canadian Institute for Health Research, National Institute of Health and the Rorabeck Chair in Vascular Biology and Neuroscience. This is the full abstract presented at the American Physiology Summit 2024 meeting and is only available in HTML format. There are no additional versions or additional content available for this abstract. Physiology was not involved in the peer review process.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».