A Multi-Country Survey on the Availability of Intraoperative Use of Echocardiography for Noncardiac Surgery
Notice bibliographique
Résumé
BACKGROUND: This survey aimed to explore the availability and accessibility of echocardiography during noncardiac surgery worldwide. METHODS: An internet-based 45-item survey was sent, followed by reminders from August 30, 2021, to August 20, 2022. RESULTS: 1189 responses were received from 62 countries. Nearly seventy-one percent of respondents had intraoperatively used transesophageal or transthoracic echocardiography (TEE and TTE, respectively) for monitoring or examination. The unavailability of echocardiography machines (30.3%), lack of trained personnel (30.2%), and absence of clinical indications (22.6%) were the top 3 reasons for not using intraoperative echocardiography in noncardiac surgery. About 61.5% of participants had access to at least one echocardiography machine. About 41% had access to at least 1 TEE probe, and 62.2% had access to at least 1 TTE probe. Seventy-four percent of centers had a procedure to request intraoperative echocardiography if needed for noncardiac cases. Intraoperative echocardiography service was immediately available in 58% of centers. CONCLUSIONS: Echocardiography machines and skilled echocardiographers are still unavailable at many centers worldwide. National societies should aim to train a critical mass of certified TEE/TTE anesthesiologists and provide all anesthesiologists access to perioperative TEE/TTE machines in anesthesiology departments, considering the increasing number of older and sicker surgical patients scheduled for noncardiac surgery.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,005 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,002 | 0,002 |
| Bibliométrie | 0,000 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».