A Handheld Tool for the Rapid Morphological Identification of Mosquito Species (VectorCam) for Community-Based Malaria Vector Surveillance: Summative Usability Study
Notice bibliographique
Résumé
BACKGROUND: Malaria impacts nearly 250 million individuals annually. Specifically, Uganda has one of the highest burdens, with 13 million cases and nearly 20,000 deaths. Controlling the spread of malaria relies on vector surveillance, a system where collected mosquitos are analyzed for vector species' density in rural areas to plan interventions accordingly. However, this relies on trained entomologists known as vector control officers (VCOs) who identify species via microscopy. The global shortage of entomologists and this time-intensive process cause significant reporting delays. VectorCam is a low-cost artificial intelligence-based tool that identifies a mosquito's species, sex, and abdomen status with a picture and sends these results electronically from surveillance sites to decision makers, thereby deskilling the process to village health teams (VHTs). OBJECTIVE: This study evaluates the usability of the VectorCam system among VHTs by assessing its efficiency, effectiveness, and satisfaction. METHODS: The VectorCam system has imaging hardware and a phone app designed to identify mosquito species. Two users are needed: (1) an imager to capture images of mosquitos using the app and (2) a loader to load and unload mosquitos from the hardware. Critical success tasks for both roles were identified, which VCOs used to train and certify VHTs. In the first testing phase (phase 1), a VCO and a VHT were paired to assume the role of an imager or a loader. Afterward, they swapped. In phase 2, two VHTs were paired, mimicking real use. The time taken to image each mosquito, critical errors, and System Usability Scale (SUS) scores were recorded for each participant. RESULTS: Overall, 14 male and 6 female VHT members aged 20 to 70 years were recruited, of which 12 (60%) participants had smartphone use experience. The average throughput values for phases 1 and 2 for the imager were 70 (SD 30.3) seconds and 56.1 (SD 22.9) seconds per mosquito, respectively, indicating a decrease in the length of time for imaging a tray of mosquitos. The loader's average throughput values for phases 1 and 2 were 50.0 and 55.7 seconds per mosquito, respectively, indicating a slight increase in time. In terms of effectiveness, the imager had 8% (6/80) critical errors and the loader had 13% (10/80) critical errors in phase 1. In phase 2, the imager (for VHT pairs) had 14% (11/80) critical errors and the loader (for VHT pairs) had 12% (19/160) critical errors. The average SUS score of the system was 70.25, indicating positive usability. A Kruskal-Wallis analysis demonstrated no significant difference in SUS (H value) scores between genders or users with and without smartphone use experience. CONCLUSIONS: VectorCam is a usable system for deskilling the in-field identification of mosquito specimens in rural Uganda. Upcoming design updates will address the concerns of users and observers.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,003 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».