The feasibility of CT simulation‐free adaptive radiation therapy
Notice bibliographique
Résumé
BACKGROUND: Novel on-board CBCT allows for improved image quality and Hounsfield unit accuracy. When coupled with online adaptive tools, this may have potential to allow for simulation and treatment to be completed in a single on-table session. PURPOSE: To study the feasibility of a high-efficiency radiotherapy treatment workflow without the use of a separate session for simulation imaging. The dosimetric accuracy, overall efficiency, and technical feasibility were used to evaluate the clinical potential of CT simulation-free adaptive radiotherapy. METHODS: Varian's Ethos adaptive radiotherapy treatment platform was upgraded with a novel CBCT system, HyperSight which reports image quality and Hounsfield unit accuracy specifications comparable to standard fan-beam CT. Using in-house developed MATLAB software, CBCT images were imported into the system and used for planning. Two test cases were completed on anthropomorphic phantoms equipped with small volume ion chambers (cross-calibrated to an ADCL traceable dose standard) to evaluate the feasibility and accuracy of the workflows. A simulated palliative spine treatment was planned with 8 Gy in one fraction, and an intact prostate treatment was planned with 60 Gy in 20 fractions. The CBCTs were acquired using HyperSight with default thorax and pelvis imaging protocols and reconstructed using an iterative algorithm with scatter removal, iCBCT Acuros. CBCTs were used for contouring and planning, and treatment was delivered via an online adaptive workflow. In addition, an external dosimetry audit was completed using only on-board CBCT imaging in an end-to-end head and neck phantom irradiation. RESULTS: An extended-field CBCT acquisition can be acquired in 12 s, in addition to the time for longitudinal table shifts, and reconstructed in approximately 1 min. The superior-inferior extent for the CBCT planning images was 38.2 cm, which captured the full extent of relevant anatomy. The contouring and treatment planning for the spine and prostate were completed in 30 and 18 min, respectively. The dosimetric agreement between ion chamber measurements and the treatment plan was within a range of -1.4 to 1.6%, and a mean and standard deviation of 0.41 ± 1.16%. All metrics used in the external audit met the passing criteria, and the dosimetric comparison between fan-beam and CBCT techniques had a gamma passing rate of 99.0% with a criteria of 2%/2 mm. CONCLUSION: Using an in-house workflow, CT simulation-free radiation therapy was shown to be feasible with acceptable workflow efficiency and dosimetric accuracy. This approach may be particularly applicable for urgent palliative treatments. With the availability of software to enable this workflow, and the continued advancement of on-treatment adaptation, single-visit radiation therapy may replace current practice for some clinical indications.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,002 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».