3M™ Defib-Pads as a Reusable Alternative to Commercial Ultrasound Gel in Resource-Limited Settings
Notice bibliographique
Résumé
INTRODUCTION: With point-of-care ultrasound (POCUS) use in austere environments comes the challenge of having an ever-available coupling medium for image generation. Commercial gel has numerous drawbacks that can limit its utility in these settings, and no studies have evaluated the potential for a reusable coupling medium. This study aimed to determine whether 3M™ Defib-Pads could be utilized as a reusable alternative to commercial gel for image generation in resource-limited settings. METHODS: A descriptive, cross-sectional survey of Canadian physicians with POCUS interest was conducted to evaluate the interpretability of various POCUS images in a blinded fashion. Three anatomic regions (cardiac, abdominal, and nerve) were utilized, and image generation from the commercial gel and 7 Defib-Pad conditions were evaluated. These included pads that were 1) newly opened, 2) dirtied then rinsed, 3) air dried, 4) rinsed after being air dried, 5) frozen then thawed, 6) used in double thickness, and 7) used with a probe cover. RESULTS: Compared to commercial gel, 3M™ Defib-Pads performed similarly, with adequate image interpretability of up to 100% in some conditions. The exception was pads that had prolonged air exposure, which produced images that were never interpretable. However, subsequent rinsing of these pads with water resulted in restored image generation. CONCLUSION: 3M™ Defib-Pads were found to produce interpretable POCUS images under multiple environmental stressors and with different modalities of use, suggesting that 3M™ Defib-Pads can perform as a reusable gel alternative in resource-limited settings.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».