Establishment and Evaluation of a Noninvasive Metabolism-Related Fatty Liver Screening and Dynamic Monitoring Model: Cross-Sectional Study
Notice bibliographique
Résumé
BACKGROUND: Metabolically associated fatty liver disease (MAFLD) insidiously affects people's health, and many models have been proposed for the evaluation of liver fibrosis. However, there is still a lack of noninvasive and sensitive models to screen MAFLD in high-risk populations. OBJECTIVE: The purpose of this study was to explore a new method for early screening of the public and establish a home-based tool for regular self-assessment and monitoring of MAFLD. METHODS: In this cross-sectional study, there were 1758 eligible participants in the training set and 200 eligible participants in the testing set. Routine blood, blood biochemistry, and FibroScan tests were performed, and body composition was analyzed using a body composition instrument. Additionally, we recorded multiple factors including disease-related risk factors, the Forns index score, the hepatic steatosis index (HSI), the triglyceride glucose index, total body water (TBW), body fat mass (BFM), visceral fat area, waist-height ratio (WHtR), and basal metabolic rate. Binary logistic regression analysis was performed to explore the potential anthropometric indicators that have a predictive ability to screen for MAFLD. A new model, named the MAFLD Screening Index (MFSI), was established using binary logistic regression analysis, and BFM, WHtR, and TBW were included. A simple rating table, named the MAFLD Rating Table (MRT), was also established using these indicators. RESULTS: The performance of the HSI (area under the curve [AUC]=0.873, specificity=76.8%, sensitivity=81.4%), WHtR (AUC=0.866, specificity=79.8%, sensitivity=80.8%), and BFM (AUC=0.842, specificity=76.9%, sensitivity=76.2%) in discriminating between the MAFLD group and non-fatty liver group was evaluated (P<.001). The AUC of the combined model including WHtR, HSI, and BFM values was 0.900 (specificity=81.8%, sensitivity=85.6%; P<.001). The MFSI was established based on better performance at screening MAFLD patients in the training set (AUC=0.896, specificity=83.8%, sensitivity=82.1%) and was confirmed in the testing set (AUC=0.917, specificity=89.8%, sensitivity=84.4%; P<.001). CONCLUSIONS: The novel MFSI model was built using WHtR, BFM, and TBW to screen for early MAFLD. These body parameters can be easily obtained using a body fat scale at home, and the mobile device software can record specific values and perform calculations. MFSI had better performance than other models for early MAFLD screening. The new model showed strong power and stability and shows promise in the area of MAFLD detection and self-assessment. The MRT was a practical tool to assess disease alterations in real time.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,016 | 0,012 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,001 |
| Méta-épidémiologie (sens large) | 0,001 | 0,001 |
| Bibliométrie | 0,001 | 0,001 |
| Études des sciences et des technologies | 0,001 | 0,000 |
| Communication savante | 0,001 | 0,001 |
| Science ouverte | 0,001 | 0,001 |
| Intégrité de la recherche | 0,001 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».