Continuous Monitoring of Heart Rate Variability and Respiration for the Remote Diagnosis of Chronic Obstructive Pulmonary Disease: Prospective Observational Study
Notice bibliographique
Résumé
BACKGROUND: Conventional daytime monitoring in a single day may be influenced by factors such as motion artifacts and emotions, and continuous monitoring of nighttime heart rate variability (HRV) and respiration to assist in chronic obstructive pulmonary disease (COPD) diagnosis has not been reported yet. OBJECTIVE: The aim of this study was to explore and compare the effects of continuously monitored HRV, heart rate (HR), and respiration during night sleep on the remote diagnosis of COPD. METHODS: We recruited patients with different severities of COPD and healthy controls between January 2021 and November 2022. Vital signs such as HRV, HR, and respiration were recorded using noncontact bed sensors from 10 PM to 8 AM of the following day, and the recordings of each patient lasted for at least 30 days. We obtained statistical means of HRV, HR, and respiration over time periods of 7, 14, and 30 days by continuous monitoring. Additionally, the effects that the statistical means of HRV, HR, and respiration had on COPD diagnosis were evaluated at different times of recordings. RESULTS: In this study, 146 individuals were enrolled: 37 patients with COPD in the case group and 109 participants in the control group. The median number of continuous night-sleep monitoring days per person was 56.5 (IQR 32.0-113.0) days. Using the features regarding the statistical means of HRV, HR, and respiration over 1, 7, 14, and 30 days, binary logistic regression classification of COPD yielded an accuracy, Youden index, and area under the receiver operating characteristic curve of 0.958, 0.904, and 0.989, respectively. The classification performance for COPD diagnosis was directionally proportional to the monitoring duration of vital signs at night. The importance of the features for diagnosis was determined by the statistical means of respiration, HRV, and HR, which followed the order of respiration > HRV > HR. Specifically, the statistical means of the duration of respiration rate faster than 21 times/min (RRF), high frequency band power of 0.15-0.40 Hz (HF), and respiration rate (RR) were identified as the top 3 most significant features for classification, corresponding to cutoff values of 0.1 minute, 1316.3 nU, and 16.3 times/min, respectively. CONCLUSIONS: Continuous monitoring of nocturnal vital signs has significant potential for the remote diagnosis of COPD. As the duration of night-sleep monitoring increased from 1 to 30 days, the statistical means of HRV, HR, and respiration showed a better reflection of an individual's health condition compared to monitoring the vital signs in a single day or night, and better was the classification performance for COPD diagnosis. Further, the statistical means of RRF, HF, and RR are crucial features for diagnosing COPD, demonstrating the importance of monitoring HRV and respiration during night sleep.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,002 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».