Assessment of the Effective Sensitivity of SARS-CoV-2 Sample Pooling Based on a Large-Scale Screening Experience: Retrospective Analysis
Notice bibliographique
Résumé
Background The development of new large-scale saliva pooling detection strategies can significantly enhance testing capacity and frequency for asymptomatic individuals, which is crucial for containing SARS-CoV-2. Objective This study aims to implement and scale-up a SARS-CoV-2 screening method using pooled saliva samples to control the virus in critical areas and assess its effectiveness in detecting asymptomatic infections. Methods Between August 2020 and February 2022, our laboratory received a total of 928,357 samples. Participants collected at least 1 mL of saliva using a self-sampling kit and registered their samples via a smartphone app. All samples were directly processed using AutoMate 2550 for preanalytical steps and then transferred to Microlab STAR, managed with the HAMILTON Pooling software for pooling. The standard pool preset size was 20 samples but was adjusted to 5 when the prevalence exceeded 2% in any group. Real-time polymerase chain reaction (RT-PCR) was conducted using the Allplex SARS-CoV-2 Assay until July 2021, followed by the Allplex SARS-CoV-2 FluA/FluB/RSV assay for the remainder of the study period. Results Of the 928,357 samples received, 887,926 (95.64%) were fully processed into 56,126 pools. Of these pools, 4863 tested positive, detecting 5720 asymptomatic infections. This allowed for a comprehensive analysis of pooling’s impact on RT-PCR sensitivity and false-negative rate (FNR), including data on positive samples per pool (PPP). We defined Ctref as the minimum cycle threshold (Ct) of each data set from a sample or pool and compared these Ctref results from pooled samples with those of the individual tests (ΔCtP). We then examined their deviation from the expected offset due to dilution [ΔΔCtP = ΔCtP – log2]. In this work, the ΔCtP and ΔΔCtP were 2.23 versus 3.33 and –0.89 versus 0.23, respectively, comparing global results with results for pools with 1 positive sample per pool. Therefore, depending on the number of genes used in the test and the size of the pool, we can evaluate the FNR and effective sensitivity (1 – FNR) of the test configuration. In our scenario, with a maximum of 20 samples per pool and 3 target genes, statistical observations indicated an effective sensitivity exceeding 99%. From an economic perspective, the focus is on pooling efficiency, measured by the effective number of persons that can be tested with 1 test, referred to as persons per test (PPT). In this study, the global PPT was 8.66, reflecting savings of over 20 million euros (US $22 million) based on our reagent prices. Conclusions Our results demonstrate that, as expected, pooling reduces the sensitivity of RT-PCR. However, with the appropriate pool size and the use of multiple target genes, effective sensitivity can remain above 99%. Saliva pooling may be a valuable tool for screening and surveillance in asymptomatic individuals and can aid in controlling SARS-CoV-2 transmission. Further studies are needed to assess the effectiveness of these strategies for SARS-CoV-2 and their application to other microorganisms or biomarkers detected by PCR.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,003 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,002 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».