Chemical State Analysis of Low-Z Elements by X-ray Photoelectron Spectroscopy (XPS)
Notice bibliographique
Résumé
X-ray photoelectron spectroscopy (XPS) is a surface analysis technique capable of providing elemental and chemical state information from the outer 5 to 10 nanometres of a solid surface. All elements from lithium to uranium can be detected with detection limits ranging from 0.1 to 3 atomic percent (element dependent). When an X-ray of known energy (hν), for example Al(Kα) at 1486.7eV, interacts with an atom, a photoelectron can be emitted via the photoelectric effect. The emitted electron’s kinetic energy (Ek) can be measured and the atomic core level binding energy (Eb) relative to the Fermi level (EF) of the sample is determined by the following equation: where Φsp is the work function of the spectrometer. Chemical information about the sample can be extracted because binding energies are sensitive to the chemical environment of the atom. Chemical environments that deshield the atom of interest (i.e. are bound to strongly electron withdrawing groups) will cause the core electrons of that atom to have increased binding energies. Conversely, decreased binding energies will be measured for core electrons of atoms that withdraw electrons from others. Essentially, binding energy will increase as chemical state number increases. XPS, with its ability to quantify elements and determine chemical states, is used in many branches of materials science, electronics, thin film chemistry, corrosion science, polymer modification, adhesion science, coating chemistry, catalysis, mineral processing chemistry, as well as in exploring fundamental aspects of the chemistry and physics of atoms and molecules. Low-Z elemental analysis by XPS, while in some ways being relatively straightforward, has some limitations with relatively high detection limits, particularly for Li, Be, B and N [1]. Semi-quantitative analysis is possible by measuring the peak areas of specific elemental core lines (I) and by applying appropriate atomic sensitivity factors (S), also known as relative sensitivity factors (RSF), using the general equation: where Cx is the atomic fraction of element x in a sample [1]. The sensitivity factors can be calculated from theory or derived empirically from the analysis of standard samples. The use of standard samples is the preferred method (which is the method applied in the Kratos line of spectrometers). Peak areas are defined by applying an appropriate background correction (e.g. linear, Shirley, Tougaard) across the binding energy range of the peaks of interest. Chemical state analysis for lithium, boron, and fluorine (e.g. Table 1) are generally accomplished using simple curve-fitting techniques of the 1s peak to derive binging energies which can then be compared to literature values in databases such as, for example, the PHI Handbook [2], the NIST XPS database [1], or the X-ray Photoelectron Spectroscopy (XPS) Reference Pages [1]. Beryllium chemical state analysis, in addition to simple curve-fitting of the main Be 1s peak, can also benefit from the use of the modified Auger parameter, which is the sum of the Be 1s peak binding energy and the Be KLL Auger peak kinetic energy. The chemical state analysis of nitrogen, carbon, and oxygen is complicated by the enormous range of chemical states possible in the vast array of organic compounds and additionally for oxygen, the myriad of possible oxide, hydroxide and oxyhydroxide compounds. Analysis of carbon species by XPS is also complicated by the presence of adventitious carbon (AdC), a thin layer of carbonaceous material that deposits on the surface of most air-exposed samples. Recent work has shown that this material is mostly aliphatic in nature with ∼ 25% of carbon species having bonds to oxygen [1]. AdC’s ubiquitous presence on most sample surfaces allows for its use in charge correction procedures but complicates the analysis of organic materials [1]. An average AdC C 1s spectrum (Figure 1), along with calculations based on sample stoichiometry, can be used to subtract out the AdC contribution, allowing for a clearer picture of the chemistries of the organic species present [5]. Typical curve-fitting of AdC starts with a single peak (Gaussian (70 %) – Lorentzian (30 %)), ascribed to alkyl type carbon (C-C, C-H), that is fit to the main peak of the C 1s spectrum. A second peak is added that is constrained to be 1.5 eV above the main peak and is of equal FWHM to the main peak. This higher B.E. peak is ascribed to alcohol (C-OH) and/or ester (C-O-C) functionality. Additional components at higher B.E., C=O, 2.8-3.0 eV above the main peak, and O-C=O, at 3.8-4.3 eV above the main peak are also usually added, again constrained to have the same FWHM as the main peak. The peak ascribed to O-C=O shows the most variation between differing samples. Analysis of materials of a graphitic nature (e.g., graphite, graphene, oxidized graphene, carbon nanotubes etc.) will benefit from advanced curve-fitting procedures. Starting curve-fitting parameters include the main peak asymmetry and π to π* shake-up satellite from a pure graphite standard sample. An example of the application of this is shown in Figure 2 for a graphene oxide material. Further analysis of carbon spectra can be done through using the D-parameter, first reported by Lascovich and colleagues [1], which describes the difference between the minimum and the maximum of the first derivative of the carbon Auger spectrum. This value has been shown to be linearly correlated to the percentage of sp2 versus sp3 hybridized carbon [1]. F 1s binding energies Average of 80 adventitious carbon (AdC) C 1s XPS spectra . An example of curve-fitting of a graphite type system, oxidized graphene .
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,001 | 0,001 |
| Études des sciences et des technologies | 0,001 | 0,000 |
| Communication savante | 0,001 | 0,001 |
| Science ouverte | 0,001 | 0,000 |
| Intégrité de la recherche | 0,001 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,005 | 0,001 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».