<scp>3D</scp> surface defect map for assessing buccolingual profile of single tooth gaps following alveolar ridge preservation
Notice bibliographique
Résumé
AIM: A new, non-invasive approach suggests using single intraoral optical scanning to analyze the ridge profile of single-tooth gaps following alveolar ridge preservation in the absence of a baseline scan. This method involves creating a three-dimensional (3D) surface map to identify and assess contour changes and ridge profiles based on the adjacent teeth. MATERIALS AND METHODS: The present study was designed as a cross-sectional pilot analysis on a convenience sample of patients undergoing alveolar ridge preservation. Intraoral optical scans were taken on 23 patients, capturing data from 30 edentulous sites. The digital models were then imported into an image analysis software for a 3D surface defect map analysis performed by one examiner. This analysis characterized the buccolingual profile of the single tooth gap relative to the adjacent teeth. 10 linear divergence points, spaced 0.5 mm apart in a corona-apical direction, were identified at the midfacial aspect of the sites. Based on these points the sites were plotted and grouped in three different buccolingual profiles (linear, concave, and convex). Clinical parameters including Keratinized mucosa Width (KMW), and soft tissue phenotype with Colorvue biotype probes were also recorded. RESULTS: Three different buccolingual patterns (linear, convex, and concave) were identified. Seven sites exhibited a linear profile, 10 sites displayed a concave shape, and 13 showed a convex profile. The linear profile had surface discrepancies similar to the neighboring teeth. In contrast, the convex profile revealed mid-buccal discrepancy localized only at the crestal aspect, while the concave had an extended divergence ranging from 1 to 5 mm below the soft tissue margin. Univariate and multiple logistic regression analyses did not reveal any statistically significant variables influencing profilometric analysis; however, when combining phenotype and KMW, thick phenotypes demonstrated a higher proportion of concavity (OR = 4.83) compared to thin ones, suggesting a significant trend. With every 1 mm of increase in KMW, the probability of showing a concavity decreased (p = 0.057). CONCLUSION: A 3D surface defect map represents a useful tool for objectively quantifying ridge defects and profiles by assessing profilometric and surface differences compared to adjacent dentition using a single intraoral scan. This method also indicates that KMW may play a critical role in preventing concavity defects. The 3D defect map can guide decision-making during soft tissue augmentation procedures by emphasizing the specific location of the defect and providing more detailed insights into its localization. These parameters can enable the tailoring of flap management and soft tissue grafting strategies to address the patient's individual needs.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,002 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,001 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,002 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».