Effect of Semaglutide on Cardiac Structure and Function in Patients With Obesity-Related Heart Failure
Notice bibliographique
Résumé
Obesity is associated with adverse cardiac remodeling and is a key driver for the development and progression of heart failure (HF). Once-weekly semaglutide (2.4 mg) has been shown to improve HF-related symptoms and physical limitations, body weight, and exercise function in patients with obesity-related heart failure with preserved ejection fraction (HFpEF), but the effects of semaglutide on cardiac structure and function in this population remain unknown. In this echocardiography substudy of the STEP-HFpEF Program, we evaluated treatment effects of once-weekly semaglutide (2.4 mg) vs placebo on cardiac structure and function. Echocardiography at randomization and 52 weeks was performed in 491 of 1,145 participants (43%) in the STEP-HFpEF Program (pooled STEP-HFpEF [Semaglutide Treatment Effect in People with Obesity and HFpEF] and STEP-HFpEF DM [Semaglutide Treatment Effect in People with Obesity, HFpEF, and Type 2 Diabetes] trials). The prespecified primary outcome was change in left atrial (LA) volume, with changes in other echocardiography parameters evaluated as secondary outcomes. Treatment effects of semaglutide vs placebo were assessed using analysis of covariance stratified by trial and body mass index, with adjustment for baseline parameter values. Overall, baseline clinical and echocardiographic characteristics were balanced among those receiving semaglutide (n = 253) and placebo (n = 238). Between baseline and 52 weeks, semaglutide attenuated progression of LA remodeling (estimated mean difference [EMD] in LA volume, −6.13 mL; 95% CI: −9.85 to −2.41 mL; P = 0.0013) and right ventricular (RV) enlargement (EMD in RV end-diastolic area: −1.99 cm 2 ; 95% CI: −3.60 to −0.38 cm 2 ; P = 0.016; EMD in RV end-systolic area: −1.41 cm 2 ; 95% CI: −2.42 to −0.40] cm 2 ; P = 0.0064) compared with placebo. Semaglutide additionally improved E-wave velocity (EMD: −5.63 cm/s; 95% CI: −9.42 to −1.84 cm/s; P = 0.0037), E/A (early/late mitral inflow velocity) ratio (EMD: −0.14; 95% CI: −0.24 to −0.04; P = 0.0075), and E/e′ (early mitral inflow velocity/early diastolic mitral annular velocity) average (EMD: −0.79; 95% CI: −1.60 to 0.01; P = 0.05). These associations were not modified by diabetes or atrial fibrillation status. Semaglutide did not significantly affect left ventricular dimensions, mass, or systolic function. Greater weight loss with semaglutide was associated with greater reduction in LA volume ( P interaction = 0.033) but not with changes in E-wave velocity, E/e′ average, or RV end-diastolic area. In the STEP-HFpEF Program echocardiography substudy, semaglutide appeared to improve adverse cardiac remodeling compared with placebo, further suggesting that treatment with semaglutide may be disease modifying among patients with obesity-related HFpEF. (Research Study to Investigate How Well Semaglutide Works in People Living With Heart Failure and Obesity [STEP-HFpEF]; NCT04788511 ; Research Study to Look at How Well Semaglutide Works in People Living With Heart Failure, Obesity and Type 2 Diabetes [STEP-HFpEF DM]; NCT04916470 )
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».