[89Zr]Zr-girentuximab for PET–CT imaging of clear-cell renal cell carcinoma: a prospective, open-label, multicentre, phase 3 trial
Notice bibliographique
Résumé
Background With limitations of conventional imaging and biopsy, accurate, non-invasive techniques to detect clear-cell renal cell carcinoma in patients with renal masses remain an unmet need. 89 Zr-labelled monoclonal antibody ([ 89 Zr]Zr-girentuximab) has high affinity for carbonic anhydrase 9, a tumour antigen highly expressed in clear-cell renal cell carcinoma. We aimed to evaluate [ 89 Zr]Zr-girentuximab PET–CT imaging for detection and characterisation of clear-cell renal cell carcinoma. Methods ZIRCON was a prospective, open-label, multicentre, phase 3 trial conducted at 36 research hospitals and practices across nine countries (the USA, Australia, Canada, the UK, Türkiye, Belgium, the Netherlands, Spain, and France). Patients aged 18 years or older with an indeterminate renal mass 7 cm or smaller (cT1) suspicious for clear-cell renal cell carcinoma and scheduled for nephrectomy received a single dose of [ 89 Zr]Zr-girentuximab (37 MBq ±10%; 10 mg girentuximab) intravenously followed by abdominal PET–CT imaging 5 days (±2 days) later. Surgery was performed no later than 90 days after administration of [ 89 Zr]Zr-girentuximab. Blinded central review, conducted by three independent readers, determined the histology from surgical samples. The coprimary endpoints, determined for each individual reader, were the sensitivity and specificity of [ 89 Zr]Zr-girentuximab PET–CT imaging to detect clear-cell renal cell carcinoma, with histopathological confirmation as standard of truth. Analyses were on the full analysis set of patients, defined as patients who had evaluable PET–CT imaging and a confirmed histopathological diagnosis. The trial is registered with ClinicalTrials.gov, NCT03849118, and EUDRA Clinical Trials Register, 2018-002773-21, and is closed to enrolment. Findings Between Aug 14, 2019, and July 8, 2022, 371 patients were screened for eligibility, 332 of whom were enrolled. 300 patients received [ 89 Zr]Zr-girentuximab (214 [71%] male and 86 [29%] female). 284 (95%) evaluable patients were included in the primary analysis. The mean sensitivity was 85·5% (95% CI 81·5–89·6) and mean specificity was 87·0% (81·0–93·1). No safety signals were observed. Most adverse events were not or were unlikely to be related to [ 89 Zr]Zr-girentuximab, with most (193 [74%] of 261 events) occurring during or after surgery. The most common grade 3 or worse adverse events were post-procedural haemorrhage (in six [2%] of 261 patients), urinary retention (three [1%]), and hypertension (three [1%]). In 25 (8%) of 300 patients, 52 serious adverse events were reported, of which 51 (98%) occurred after surgery. There were no treatment-related deaths. Interpretation Our results suggest that [ 89 Zr]Zr-girentuximab PET–CT has a favourable safety profile and is a highly accurate, non-invasive imaging modality for the detection and characterisation of clear-cell renal cell carcinoma, which has the potential to be practice changing. Funding Telix Pharmaceuticals.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».