Scatter correction based on time-of-flight measurements for radiography and photon counting CT
Notice bibliographique
Résumé
Time-of-flight (ToF) CT and radiography are explored as a novel method for scatter estimation and correction for state-of-the-art medical X-ray imaging with increased sensitivity. By measuring the ToF of X photons from the source to the detector, the scattered contribution can be estimated in each pixel individually, owing to the longer paths taken by scattered X photons. While an entire scan can be made this way, there is some concern about the duration of the acquisition since measuring ToF requires a pulsed X-ray source with a very low duty cycle (1-5%). As an alternative, this paper explores the use of ToF-CT to correct for scatter contribution in a regular photon counting projection image. It is validated at different timing resolutions and for different ToF scan durations using Monte Carlo simulations performed with GATE. The results show that with a 10 ps FWHM timing resolution, the method is capable of accurately estimating and correcting for $98 \%$ of the scatter while keeping a sensitivity to primary photons over $98 \%$ in photon counting mode. Between 50 and 150 ps, the scatter correction performance is comparable to an anti-scatter grid’s, but without any loss in sensitivity.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,003 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,001 | 0,001 |
| Science ouverte | 0,001 | 0,000 |
| Intégrité de la recherche | 0,001 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,002 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».