Assessing the Performance of the TOFPET2c ASIC at X-ray Energies for Time-of-Flight Scatter Rejection Applications
Notice bibliographique
Résumé
The addition of a time-of-flight (ToF) measurements to radiography and computed tomography (CT) opens the door to an anti-scatter grid-free approach to scatter rejection in imaging systems, potentially increasing system sensitivity and image quality. Previously developed hardware limited to a few channels showed that the ToF scatter rejection is possible, but lacked in scale and density. A medium-scale ToF scatter rejection detection module was developed, allowing for the evaluation of off-the-shelf ToF ASICs, as well as the future development of dedicated devices. The TOFPET2c ASIC designed by PETSys showed good potential for the first detector, offering high integration and pixel count. The evaluation of the TOFPET2c ASIC at X-ray energies (20 keV to 140 keV) showed a 414 ps FWHM detector timing resolution. Such a value is slightly over the 300 ps FWHM limit sufficient to reach scatter-rejection similar to anti-scatter grids and requires further investigation. An energy resolution bellow 50% was also reached for all desired energies.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».