Molecular engineering of a fluorescent probe for highly efficient detection of human serum albumin in biological fluid
Pourquoi ce travail est dans la base
Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.
Notice bibliographique
Résumé
Human serum albumin (HSA) is synthesized by the liver, accounting for 60 % of total plasma protein in vertebrates' blood. It is the most predominant extracellular plasma protein that acts as a repository and transporter of exogenous and endogenous substances in the blood of healthy humans. Decreased albumin concentration in the human body or its abnormal levels indicate the occurrence of hepatic, renal, and digestive-related diseases. Therefore, accurate quantification of HSA is of great significance in diagnostic testing and routine clinical analysis of albumin-linked diseases. Herein, a class of triphenylamine rhodanine-3-acetic acid (mRA)-a bifunctional fluorescent molecule with twisted intramolecular charge transfer (TICT)-induced emission characteristics is synthesized and employed as a novel sensing probe for the fluorescent detection of human albumin. mRA can be selectively lighted up through site-specific interactions with serum albumin-binding moieties and show enhanced photophysical or biological response efficacy. Understanding the interaction of mRA with HSA at the molecular level was carried out using docking methodology to explore the site-specific interaction phenomenon. The resulting fluorescence strategy produced a dose-dependent signal response enhancement upon interaction with HSA in the concentration range of 0.01–400 μg/ml. The sensor probe exhibits a low detection limit of 10 ng/mL and is found to be a feasible, low-cost, and effective approach for HSA analysis in complex biological fluids for early detection and diagnosis of albumin-related diseases. Human serum albumin (HSA) levels in plasma are one of the important indicators of liver function. HSA-induced Turn-on fluorescence emission of Triphenylamine rhodanine-3-acetic acid (mRA) exploited for the quantitative detection of HSA. The affinity and selective binding of mRA with HSA have been demonstrated. • A simple fluorescence-based quantitative detection of Human serum albumin has been demonstrated •Triphenylamine rhodanine-3-acetic acid (mRA)- with twisted intramolecular charge transfer (TICT)- employed as a novel sensing probe • A fifty-fold enhancement in the fluorescence of the probe dye by HSA facilitates the low limit of detection •The probe dye has high affinity and specificity for HSA without any cross-reactivity of other closely associated biomolecules. •This method has been used for the analysis of the biological fluid derived from liver cancer cell supernatants
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle