Portable X-ray fluorescence of zinc and selenium with nail clippings–Mother and Infant Nutrition Investigation (MINI)
Notice bibliographique
Résumé
Zinc and selenium are essential minerals for human nutrition. Reliable biomarkers of zinc status and selenium status in humans are therefore important. This work investigates a novel portable X-ray fluorescence (XRF) method with the ability to rapidly assess zinc and selenium in nail clippings. This approach used a mono-energetic X-ray beam to excite characteristic X-rays from the clippings. Nail clippings were obtained from the Mother and Infant Nutrition Investigation (MINI), a study designed to assess nutrition in a population of women and their breastfed children in New Zealand. Twenty mother-infant pairings were selected to provide nail clippings at two time points (visit 1 at 3 months postpartum; visit 2 at 6 months postpartum). Nail clippings from each mother-infant pairing were divided into three groupings of clippings prior to analysis: those obtained from a big toe of the mother, those from the other toes of the mother, and those from the toes and fingers of the infant. Clippings were prepared and mounted prior to XRF measurement, providing four distinct fragments from each clipping grouping. These fragments were assessed by XRF using a measurement time of either 300 s (visit 1) or 180 s (visit 2). XRF results were determined through both an automated system output and an analysis of the X-ray energy spectrum. Following this assessment of zinc and selenium with the non-destructive XRF method, clippings were measured for zinc and selenium concentration using a "gold standard" technique of inductively coupled plasma mass spectrometry (ICP-MS). Mean ICP-MS concentrations ranged from 122 μg/g to 127 μg/g for zinc, and from 0.646 μg/g to 0.659 μg/g for selenium. Precision, assessed by a relative standard deviation of measurement, was superior for ICP-MS relative to XRF. For both zinc and selenium, XRF results were compared with ICP-MS concentrations. Linear equations of best fit were determined for each comparison between XRF and ICP-MS results. Coefficients of determination (r2) were stronger for zinc (from 0.74 to 0.95) than selenium (from 0.53 to 0.70). A decrease in XRF measurement time from 300 s to 180 s did not appear to adversely affect the correlation between XRF and ICP-MS results. Using the mono-energetic portable XRF method, the correlation of XRF zinc results with ICP-MS zinc concentrations was improved over previous findings, and selenium measurement was reported for the first time. The method may prove useful for future applications to trace element analysis using nail clippings as a biomarker.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,001 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,001 | 0,000 |
| Intégrité de la recherche | 0,001 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,003 | 0,001 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».