Permanent DAS/DTS Monitoring for SAGD Production – Design, Results, and Recommendations
Notice bibliographique
Résumé
Abstract Designs and preliminary results from a multi-year project for simultaneous Distributed Acoustic Sensing (DAS) and Distributed Temperature Sensing (DTS) executed across multiple wells on a Steam-Assisted Gravity Drainage (SAGD) field in Canada is presented. Primary objectives of the project were to demonstrate prototypical execution of DAS and DTS data collection on a standard SAGD pad setup and to characterize inflow across the production zone. Challenges and learnings from this technically demanding project are explored alongside a discussion on the improving viability of continuous acoustic monitoring to augment temperature sensing commonly utilized in SAGD instrumentation design. The DTS technique employs a combination of an optoelectronics topside instrument and a downhole sensing fiber to produce a distributed temperature profile of the fiber string. The topside instrument comprises a laser light source, a fast optical detector and a combination of electrical and optical circuits to control light pulsing, and the detection and measurements of Raman backscattered light containing encoded temperature information about the temperature profile. The sensing fiber type is selected based on suitability with the topside instrument and the expected maximum operating temperature of its intended sensing environment. While DTS is compatible with both single-mode (SM) and multi-mode (MM) fiber type, MM graded-index fibers are often selected for SAGD environment due to its larger optical core size. Using a MM fiber allows for increased capture of the backscatter Raman light, a much weaker light signal than the laser light launched into the optical fiber. Temperature dependent Raman signals are extracted from the returned light and by applying the Optical Time Domain Reflectometry (OTDR) technique, which produces a temperature trace consisting of temperature magnitude matched to each unit distance along the sensing fiber. The temperature trace can vary in its spatial resolution subject to the topside instrument configuration with typical resolving resolution between 0.5 – 1.5 meters. Other general DTS sensing techniques are described in the literature (for example, Hartog (2017)) but are not described here. Some of the earliest uses of DTS in thermal enhanced oil recovery (EOR) was to monitor steam breakthrough and pump vapor locking in California's steam flood as reported by Carnahan (1999). Since then, advancement in specialty fiber optics suitable for thermal environment upwards to 300°C has enabled mainstream adoption within SAGD. Uses of DTS data has expanded to include, but not limited to, monitoring of well and steam chamber conformance, tubing and casing integrity, gas ingression and water coning. DAS is an optical interferometry technique employing an optoelectronics topside instrument and a downhole sensing fiber to detect minute changes in fiber length at each location along the fiber string. The instrument is sensitive at the pico-strain (ρε) level with a spatial resolution equal to a configurable distance referred to as the gauge length. The term "acoustic" in Distributed Acoustic Sensing broadly designates any mechanical perturbation able to alter the local state of strain anywhere along the optical fiber, be it from dynamic pressure changes, or dynamic strain (e.g. vibration). While DAS is compatible with both SM and MM fiber type, deployment alongside SM fiber types have been traditionally preferred as the laser light coherence is better preserved throughout its round-trip propagation compared to MM fiber. However, DAS with MM fiber can still be used for typical fiber lengths in SAGD wells without significant penalty in signal quality as shown in literatures (MacPhail (2016), Burke (2022). This cross-compatibility with MM fiber allows collection of DAS on existing DTS fibers deployments without further intervention. Prior to DAS adoption in oil and gas, it was predominantly deployed in defense and security application to perform parameter monitoring and ground disturbance detection. As DAS technology evolved, it was first trialed in Shell's unconventional tight gas wells in February 2009 to monitor plug setting, perforation shots and active clusters during fracking operation (Molenaar et al. 2012). In EOR application like SAGD, DAS provides an augmenting dataset correlating to production inflow phases (MacPhail et al. 2016) which would not be readily detectable in the temperature domain alone. Efforts like the one presented in this paper are underway to progress horizontal inflow profiling and inferred relative volumes which aids in understanding well productivity and efficacy of added inflow control devices (ICD). Unlike DTS, acoustic data is largely unaffected by temperature masking due to well completions. For events where insufficient temperature deviation are produced, DAS may be used to surveille for common industry challenges such as steam coning, gas ingression, loss of tubing/casing integrity and more. The emerging market segment for Carbon Capture and Underground Storage (CCUS) is poised to utilize DAS as one of the many leak detection toolkit for the injection monitoring wells.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,003 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,001 |
| Bibliométrie | 0,001 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,001 |
| Communication savante | 0,002 | 0,001 |
| Science ouverte | 0,002 | 0,001 |
| Intégrité de la recherche | 0,001 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,004 | 0,002 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».