8 Single centre review of magnetic resonance imaging (MRI) in paediatric patients (<18 yrs) with cardiac implantable electronic devices (CIEDs)

2024· article· en· W4405227155 sur OpenAlexaboutno aff
Sylvia Krupičková, Evgenia Nikolou, Raad H. Mohiaddin, Francisco Alpendurada, Cemil İzgi, Janice Till, Ka Sing Wong, Tsveta Rahneva, S. Wallis, Dudley J. Pennell, John Baksi

Notice bibliographique

Revuenon disponible
Typearticle
Langueen
DomaineMedicine
ThématiqueCardiac pacing and defibrillation studies
Établissements canadiensnon disponible
Organismes subventionnairesnon disponible
Mots-clésMagnetic resonance imagingMedicineCardiac magnetic resonanceNuclear magnetic resonanceRadiologyPhysics

Résumé

récupéré en direct d'OpenAlex

Introduction Guidelines have been developed by the Heart Rhythm Society, Joint British Societies and other national societies for performing MRI in patients with CIEDs. All exclude specific guidance for children, due to theoretical risks of harm in smaller body size with predominantly epicardial leads from in vitro studies. Although evidence is growing for epicardial systems there remains a paucity of published evidence for the safety of MRI with CIED in the paediatric population and no clear recommendations. Our primary aim was to elicit the feasibility and safety of MRI in paediatric patients with CIEDs at our centre within the last 10 years. Materials and Methods Retrospective review of all patients under 18 years of age who underwent MRI with a CIED at a tertiary cardiac centre. No scans were performed under sedation or general anaesthetic. All scans were performed at 1.5 Tesla in Normal mode with SAR<2 W/kg and pacing parameters were altered for the duration of the scan in accordance with local guidelines. Adverse events were defined as a significant change in lead impedance, battery life or physical symptoms. Results 12 children between 10–17 yrs, mean 14.3 yrs, with CIED underwent MRI. No patients were pacemaker dependent. 14 scans were performed with no adverse events. Mean length of scan 49 mins (IQR 43–60). Mean BSA 1.59 m2 (IQR 1.37 – 1.69). Discussion All scans were performed without adverse events demonstrating an acceptable safety profile for appropriately selected paediatric patients with CIED, provided local guidelines are strictly adhered to. Within this group, there were no patients under 10 ys, no abdominal generators, and only 1 epicardial lead. 28% of scans did not provide diagnostic information with significant artefact obscuring the region of interest, notably, S-ICD generators obscured most of the left ventricle for 2 cardiac MRI. Conclusion Although predominantly limited to endocardial or subcutaneous systems in older children, this data contributes to the growing evidence of safety in performing MRI scans for children with CIED, despite theoretical concerns about increased adverse effects with lower weight/BSA. However, significant generator-related artefact can reduce the diagnostic utility of cardiac MRI. Further safety and imaging data to better inform patient selection is desirable. References Indik JH, Gimbel JR, Haruhiko A, et al. 2017 HRS expert consensus statement on magnetic resonance imaging and radiation exposure in patients with cardiovascular implantable electronic devices. Heart Rhythm 2017;14(7) doi:10.1016/j.hrthm.2017.04.025 Bhuva A, Charles-Edwards G, Ashmore J, et al. Joint British society consensus recommendations for magnetic resonance imaging for patients with cardiac implantable electronic devices. Heart 2022;0:1–17. doi:10.1136/heartjnl-2022-320810. Vigen KK, Reeder SB, Hood MN, et al. JMRI-ISMRM Recommendations for imaging patients with cardiac implantable electronic devices (CIEDs). J Magn Reason Imaging 2020. Levine GN, Gomes AS, Arai AE, et al. Safety of magnetic resonance imaging in patients with cardiovascular devices: an American heart association scientific statement from the committee on diagnostic and interventional cardiac catheterization, council on clinical cardiology, and the council on cardiovascular radiology and intervention: endorsed by the American college of cardiology foundation, the North american society for cardiac imaging, and the society for cardiovascular magnetic resonance. Circulation 2007;116:2878–2891. Verma A, Ha AC, Dennie C, et al. Canadian heart rhythm society and Canadian association of radiologists consensus statement on magnetic resonance imaging with cardiac implantable electronic devices. Can Assoc Radiol J 2014;65:290–300.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction machine sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.

score de la tête « metaresearch » (Codex)0,002
score de la tête « metaresearch » (Gemma)0,011
Version: metacan-v3-hybrid-931329e0061cStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Observationnel · Signal consensuel: aucune
GenreSignal candidat: Synthèse · Signal consensuel: Synthèse
Score de désaccord entre enseignants0,004
Score d'incertitude au seuil0,011

Scores du classifieur distillé par catégorie (deux têtes)

CatégorieCodexGemma
Métarecherche0,0020,011
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0010,001
Bibliométrie0,0040,005
Études des sciences et des technologies0,0000,000
Communication savante0,0010,001
Science ouverte0,0010,000
Intégrité de la recherche0,0010,000
Charge utile insuffisante (le modèle a refusé de juger)0,0030,001

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,007
Tête enseignante GPT0,243
Écart entre enseignants0,236 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeObservationnel
Domainenon disponible
GenreSynthèse

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations0
Publié2024
Routes d'admission1
Résumé présentoui

Explorer davantage

Même sujetCardiac pacing and defibrillation studies→Travaux en français237 207→