MétaCan
Menu
Retour à la cohorte
Enregistrement W4406211789 · doi:10.1007/s00216-024-05699-7

Commutability assessment of new standard reference materials (SRMs) for determining serum total 25-hydroxyvitamin D using ligand binding and liquid chromatography–tandem mass spectrometry (LC–MS/MS) assays

2025· article· en· W4406211789 sur OpenAlexaff
Stephen A. Wise, Etienne Cavalier, Pierre Lukas, Stéphanie Peeters, Caroline Le Goff, Laura E. Briggs, Emma L. Williams, Ekaterina Mineva, Christine M Pfeiffer, Hubert W. Vesper, Christian Popp, Christian Beckert, Jan Schultess, Kevin Wang, Carole Tourneur, Camille Pease, Dominik Osterritter, Ralf Fischer, Ben Saida, Chao Dou, Satoshi Kojima, Hope A. Weiler, A Bielecki, Heather Pham, Alexandra Bennett, Amit Ghoshal, Bin Wei, Christian Vogl, James Freeman, Neil H. Parker, Samantha Pagliaro, Jennifer Cheek, Jinghong Li, Hisao Tsukamoto, Karen Galvin, Kevin D. Cashman, Hsuan-Chieh Liao, Andrew N. Hoofnagle, Jeffery R. Budd, Adam J. Kuszak, Ashley S.P. Boggs, Carolyn Q Burdette, Grace Hahm, Federica Nalin, Johanna E Camara

Notice bibliographique

RevueAnalytical and Bioanalytical Chemistry · 2025
Typearticle
Langueen
DomaineMedicine
ThématiqueVitamin D Research Studies
Établissements canadiensHealth Canada
Organismes subventionnairesNational Institutes of HealthNational Institute of Standards and TechnologyOffice of Dietary Supplements
Mots-clésChemistryAnalyteChromatographyVitamin D and neurologyVitamin D-binding proteinLiquid chromatography–mass spectrometryReference valuesTandem mass spectrometryMass spectrometryVitaminMedicineInternal medicineBiochemistry

Résumé

récupéré en direct d'OpenAlex

Abstract Commutability is where the measurement response for a reference material (RM) is the same as for an individual patient sample with the same concentration of analyte measured using two or more measurement systems. Assessment of commutability is essential when the RM is used in a calibration hierarchy or to ensure that clinical measurements are comparable across different measurement procedures and at different times. The commutability of three new Standard Reference Materials® (SRMs) for determining serum total 25-hydroxyvitamin D [25(OH)D], defined as the sum of 25-hydroxyvitamin D2 [25(OH)D2] and 25-hydroxyvitamin D3 [25(OH)D3], was assessed through an interlaboratory study. The following SRMs were assessed: (1) SRM 2969 Vitamin D Metabolites in Frozen Human Serum (Total 25-Hydroxyvitamin D Low Level), (2) SRM 2970 Vitamin D Metabolites in Frozen Human Serum (25-Hydroxyvitamin D2 High Level), and (3) SRM 1949 Frozen Human Prenatal Serum. These SRMs represent three clinically relevant situations including (1) low levels of total 25(OH)D, (2) high level of 25(OH)D2, and (3) 25(OH)D levels in nonpregnant women and women during each of the three trimesters of pregnancy with changing concentrations of vitamin D-binding protein (VDBP). Twelve laboratories using 17 different ligand binding assays and eight laboratories using nine commercial and custom liquid chromatography–tandem mass spectrometry (LC–MS/MS) assays provided results in this study. Commutability of the SRMs with patient samples was assessed using the Clinical and Laboratory Standards Institute (CLSI) approach based on 95% prediction intervals or a pre-set commutability criterion and the recently introduced International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) approach based on differences in bias for the clinical and reference material samples using a commutability criterion of 8.8%. All three SRMs were deemed as commutable with all LC–MS/MS assays using both CLSI and IFCC approaches. SRM 2969 and SRM 2970 were deemed noncommutable for three and seven different ligand binding assays, respectively, when using the IFCC approach. Except for two assays, one or more of the three pregnancy levels of SRM 1949 were deemed noncommutable or inconclusive using different ligand binding assays and the commutability criterion of 8.8%. Overall, a noncommutable assessment for ligand binding assays is determined for these SRMs primarily due to a lack of assay selectivity related to 25(OH)D2 or an increasing VDBP in pregnancy trimester materials rather than the quality of the SRMs. With results from 17 different ligand binding and nine LC–MS/MS assays, this study provides valuable knowledge for clinical laboratories to inform SRM selection when assessing 25(OH)D status in patient populations, particularly in subpopulations with low levels of 25(OH)D, high levels of 25(OH)D2, women only, or women who are pregnant. Graphical Abstract

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction machine sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.

score de la tête « metaresearch » (Codex)0,047
score de la tête « metaresearch » (Gemma)0,053
Version: metacan-v3-hybrid-931329e0061cStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Expérimental (laboratoire) · Signal consensuel: Expérimental (laboratoire)
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,047
Score d'incertitude au seuil0,247

Scores du classifieur distillé par catégorie (deux têtes)

CatégorieCodexGemma
Métarecherche0,0470,053
Méta-épidémiologie (sens strict)0,0020,001
Méta-épidémiologie (sens large)0,0010,001
Bibliométrie0,0040,002
Études des sciences et des technologies0,0010,002
Communication savante0,0020,001
Science ouverte0,0030,002
Intégrité de la recherche0,0030,001
Charge utile insuffisante (le modèle a refusé de juger)0,0010,001

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,035
Tête enseignante GPT0,357
Écart entre enseignants0,322 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeExpérimental (laboratoire)
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations7
Publié2025
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueAnalytical and Bioanalytical ChemistryMême sujetVitamin D Research StudiesTravaux en français237 207