P0253 Identification of baseline Pediatric Crohn’s disease location and complications: How do intestinal ultrasound and magnetic resonance enterography compare?
Notice bibliographique
Résumé
Abstract Background Pediatric patients with newly diagnosed Crohn’s disease (CD) often undergo magnetic resonance enterography (MRE) to assess bowel not accessible by endoscopy and to evaluate for CD complications. In contrast to intestinal ultrasound (IUS), MRE access is quite limited, expensive, and not feasible for young patients. Little is known about how MRE and IUS compare, with a recent systematic review reporting inconclusive results when comparing diagnostic accuracy in pediatric CD. This study therefore aimed to compare MRE and IUS at diagnosis of pediatric CD. Methods Pediatric patients (≤18 years old) seen for suspected CD were prospectively consecutively enrolled (2019-2022) and underwent endoscopy (Simple Endoscopic Score for Crohn Disease (SES-CD)), MRE, IUS (performed by IUS trained pediatric gastroenterologists), calprotectin, blood work and assessment (weighted Pediatric Crohn Disease Activity Index (wPCDAI)). A blinded pediatric radiologist read all MREs. An interim analysis was done after 21 patients before the final analysis. Statistical analyses included descriptive statistics and Pearson chi-square. Results 58 patients (n=38, 66% male) were included; median age 13 years (IQR 10-15, range 6-17). Disease activity at diagnosis was moderate: median SES-CD 14 (IQR 10-21), wPCDAI 48 (IQR 34-59), calprotectin 1455ug/g (IQR 840-2454), C-reactive protein 47mg/L (IQR 27-72), and erythrocyte sedimentation rate 33mm/hr (IQR 18-46). Jejunum and proximal ileum involvement had high levels of agreement between MRE and IUS for non-inflamed bowel, but less agreement for inflammation (Figure 1). There was higher agreement for inflamed distal ileum compared to proximal ileum or jejunum (Figure 1). MRE and IUS performed similarly in identifying endoscopically inflamed bowel, with the highest accuracy for the terminal ileum (TI) (Figure 2). Both were more accurate for moderate/severe (segment SES-CD≥7) vs. mild/moderate/severe disease (segment SES-CD≥3) (Figure 2). For patients with endoscopic TI strictures (n=8/58, 14%), this was seen on MRE (n=8/8, 100%) more often than IUS (n=5/8, 63%). Those without endoscopic TI strictures were still reported on MRE (n=15/50, 30%), more than IUS (n=2/50, 4%). There were no significant differences in MRE vs. IUS bowel wall thickness measurements in all segments of the small and large bowel (p>0.05). Conclusion IUS and MRE performed similarly in distal small bowel and colonic CD assessment in both the identification and measurement of inflamed bowel. More proximal small bowel disease may be over reported by MRE or under reported by IUS. MRE also over reported TI stricturing disease. Both may miss mild CD. For initial and longitudinal pediatric CD assessment, repeating IUS rather than MRE is a viable option.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,005 | 0,021 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,001 |
| Bibliométrie | 0,002 | 0,003 |
| Études des sciences et des technologies | 0,000 | 0,001 |
| Communication savante | 0,001 | 0,001 |
| Science ouverte | 0,001 | 0,001 |
| Intégrité de la recherche | 0,001 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,002 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».