MétaCan
Menu
Retour à la cohorte
Enregistrement W4406792383 · doi:10.1002/uog.29178

Intra‐ and interobserver agreement of proposed objective transvaginal ultrasound image‐quality scoring system for use in artificial intelligence algorithm development

2025· article· en· W4406792383 sur OpenAlexaff
Alison Deslandes, Jodie Avery, Hou‐Tong Chen, Mathew Leonardi, Steven Knox, Glen Lo, Rebecca O’Hara, G. Condous, M. Louise Hull

Notice bibliographique

RevueUltrasound in Obstetrics and Gynecology · 2025
Typearticle
Langueen
DomaineMedicine
ThématiqueOvarian function and disorders
Établissements canadiensMcMaster University
Organismes subventionnairesUniversity of AdelaideAustralian Government
Mots-clésIntraclass correlationUltrasoundKappaCohen's kappaImage qualityMedicineArtificial intelligenceAlgorithmImage (mathematics)Medical physicsMachine learningRadiologyComputer scienceMathematicsReproducibilityStatistics

Résumé

récupéré en direct d'OpenAlex

OBJECTIVES: The development of valuable artificial intelligence (AI) tools to assist with ultrasound diagnosis depends on algorithms developed using high-quality data. This study aimed to test the intra- and interobserver agreement of a proposed image-quality scoring system to quantify the quality of gynecological transvaginal ultrasound (TVS) images, which could be used in clinical practice and AI tool development. METHODS: A proposed scoring system to quantify TVS image quality was created following a review of the literature. This system involved a score of 1-4 (2 = poor, 3 = suboptimal and 4 = optimal image quality) assigned by a rater for individual ultrasound images. If the image was deemed inaccurate, it was assigned a score of 1, corresponding to 'reject'. Six professionals, including two radiologists, two sonographers and two sonologists, reviewed 150 images (50 images of the uterus and 100 images of the ovaries) obtained from 50 women, assigning each image a score of 1-4. The review of all images was repeated a second time by each rater after a period of at least 1 week. Mean scores were calculated for each rater. Overall interobserver agreement was assessed using intraclass correlation coefficient (ICC), and interobserver agreement between paired professionals and intraobserver agreement for all professionals were assessed using weighted Cohen's kappa and ICC. RESULTS: Poor levels of interobserver agreement were obtained between the six raters for all 150 images (ICC, 0.480 (95% CI, 0.363-0.586)), as well as for assessment of the uterine images only (ICC, 0.359 (95% CI, 0.204-0.523)). Moderate agreement was achieved for the ovarian images (ICC, 0.531 (95% CI, 0.417-0.636)). Agreement between the paired sonographers and sonologists was poor for all images (ICC, 0.336 (95% CI, -0.078 to 0.619) and 0.425 (95% CI, 0.014-0.665), respectively), as well as when images were grouped into uterine images (ICC, 0.253 (95% CI, -0.097 to 0.577) and 0.299 (95% CI, -0.094 to 0.606), respectively) and ovarian images (ICC, 0.400 (95% CI, -0.043 to 0.669) and 0.469 (95% CI, 0.088-0.689), respectively). Agreement between the paired radiologists was moderate for all images (ICC, 0.600 (95% CI, 0.487-0.693)) and for their assessment of uterine images (ICC, 0.538 (95% CI, 0.311-0.707)) and ovarian images (ICC, 0.621 (95% CI, 0.483-0.728)). Weak-to-moderate intraobserver agreement was seen for each of the raters with weighted Cohen's kappa ranging from 0.533 to 0.718 for all images and from 0.467 to 0.751 for ovarian images. Similarly, for all raters, the ICC indicated moderate-to-good intraobserver agreement for all images overall (ICC ranged from 0.636 to 0.825) and for ovarian images (ICC ranged from 0.596 to 0.862). Slightly better intraobserver agreement was seen for uterine images, with weighted Cohen's kappa ranging from 0.568 to 0.808 indicating weak-to-strong agreement, and ICC ranging from 0.546 to 0.893 indicating moderate-to-good agreement. All measures were statistically significant (P < 0.001). CONCLUSION: The proposed image quality scoring system was shown to have poor-to-moderate interobserver agreement and mostly weak-to-moderate levels of intraobserver agreement. More refinement of the scoring system may be needed to improve agreement, although it remains unclear whether quantification of image quality can be achieved, given the highly subjective nature of ultrasound interpretation. Although some AI systems can tolerate labeling noise, most will favor clean (high-quality) data. As such, innovative data-labeling strategies are needed. © 2025 The Author(s). Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,001
score de la tête « metaresearch » (Gemma)0,010
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesMétarecherche
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Observationnel · Signal consensuel: aucune
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,660
Score d'incertitude au seuil0,999

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0010,010
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0000,000
Bibliométrie0,0010,001
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,034
Tête enseignante GPT0,296
Écart entre enseignants0,262 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Devis d'étudeObservationnel
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations7
Publié2025
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueUltrasound in Obstetrics and GynecologyMême sujetOvarian function and disordersTravaux en français237 207