Biobeat monitor utilization in various healthcare settings: A systematic review
Notice bibliographique
Résumé
Background: Ensuring accurate and continuous monitoring of patients' physiological parameters is paramount for evaluating their health status and guiding clinical decision-making. Technological advancements have the potential to significantly improve patient care and outcomes by offering a seamless continuum of healthcare experiences. Biobeat Technologies Ltd has pioneered a non-invasive wearable approach to acquiring advanced hemodynamic parameters, employing devices such as the BB-613WP wrist monitor and the BB-613P chest patch. Biobeat devices have been applicable across many clinical settings, as substantiated by a growing body of research. This systematic review endeavours to comprehensively consolidate the evidence regarding using Biobeat monitors across various clinical scenarios. Methods: From 2016 to 2024, a thorough literature search was conducted across multiple databases. The inclusion criteria for selected studies comprised adult patients aged 18 years or older in any healthcare setting, employing Biobeat monitoring devices (wrist monitors and/or chest patches), reporting at least one outcome or finding, and presenting fully published original research studies, including randomized controlled trials and prospective or retrospective cohort studies. The quality and risk of bias assessment for the studies was performed using the Newcastle-Ottawa scale and COSMIN scoring system. Results: Among 27 studies identified, 15 met the inclusion criteria, involving 4248 patients. These included 14 prospective observational studies and one retrospective cohort study; no randomized control trials were identified. Notably, eight studies were conducted in ambulatory settings, with 1 study focusing on patients undergoing labor and delivery. Additionally, three studies were carried out in general inpatient wards, 1 in a medical ICU and another in a cardiac surgery ICU (CSICU). Furthermore, 1 study presented results from 3 separate investigations- 2 in ambulatory settings and 1 in the CSICU. Across all studies, Biobeat devices were consistently utilized, with each study reporting positive outcomes associated with their use. Conclusion: This systematic review demonstrates that Biobeat's non-invasive wearable devices have been effectively utilized across various clinical settings, consistently contributing to positive patient outcomes. The versatility and reliability of these devices highlight their potential to enhance patient care and support clinical decision-making, warranting further research to explore their broader applications.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,001 |
| Méta-épidémiologie (sens large) | 0,004 | 0,000 |
| Bibliométrie | 0,001 | 0,002 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».