Real‐time radiation beam imaging on an MR linear accelerator using quantitative <i>T</i> <sub>1</sub> mapping
Notice bibliographique
Résumé
Abstract Background Direct three‐dimensional imaging of radiation beams could enable more accurate radiation dosimetry. It has been previously reported that changes in T 1 ‐weighted magnetic resonance imaging (MRI) intensity could be observed during radiation due to radiochemical oxygen depletion. Quantitative T 1 mapping could increase sensitivity for dosimetry applications. Purpose We use an MRI linear accelerator (MR‐Linac) to visualize radiation delivery through the real‐time effects of dose on the spin‐lattice magnetic relaxation time ( T 1 ) of water. We quantify the relationships between dose, spin‐lattice relaxation rates ( R 1 ) and dissolved oxygen concentration to further investigate the mechanisms of T 1 change. Methods An ultrapure water phantom and a 1% agarose gel phantom were irradiated and imaged on a 1.5 T Elekta Unity MR‐Linac. Radiation plans were created using the Monaco treatment planning system. Images were acquired before, during and after radiation. A dual‐echo Look‐Locker inversion recovery pulse sequence was used for simultaneous dynamic T 1 / B 0 mapping. The change in R 1 with respect to dose (∆ R 1 /∆Dose) and the radiochemical oxygen depletion (ROD = ∆O 2 /∆Dose) were measured. The relaxivity of oxygen ( r 1,O2 = ∆ R 1 /∆O 2 ) in water was also measured in a separate experiment with samples of various dissolved oxygen concentrations. The minimum measurable dose over a 20‐min period was estimated using a single‐tailed 99th quantile Student's t ‐distribution. Results Changes to R 1 were found to be spatiotemporally correlated to the predicted delivered radiation dose and persisted for at least 1 h after radiation. A complex dose plan could be imaged in the 1% agarose gel phantom, as the gel limits diffusion and convective mixing. In water, the ∆ R 1 /∆Dose was found to be −1.0 × 10 −4 s −1 /Gy, the r 1,O2 was found to be 5.4 × 10 −3 s −1 /(mg/L), and the ROD was found to be −0.010 (mg/L)/Gy. Both r 1,O2 and ROD agree with published values. However, combining these two values yields a predicted ∆ R 1 /∆Dose of −5.4 × 10 −5 s −1 /Gy, indicating that radiochemical oxygen depletion alone under‐predicts the MRI effect. The detection limit of R 1 was 1.1 × 10 −3 s −1 which corresponded to a single‐voxel minimum detectable dose of 11.1 Gy for this specific sequence. Conclusion Quantitative T 1 mapping was used to image radiation dose patterns in real‐time in water and agarose gel. Radiochemical oxygen depletion only partially explains the T 1 changes measured. Agarose gel could be used as a simple system for three‐dimensional patient‐specific quality assurance. Future applications may include in vivo dosimetry for FLASH radiotherapy, though improvements in acquisition methods and hardware are likely needed.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,001 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,001 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,002 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».