MétaCan
Menu
Retour à la cohorte
Enregistrement W4408076477 · doi:10.3310/htbt7685

Optimisation of the deployment of automated external defibrillators in public places in England

2025· article· en· W4408076477 sur OpenAlexaff
Terry Brown, Lazaros Andronis, Asmaa El-Banna, Kwan Leung, Theodoros N. Arvanitis, Charles D. Deakin, A Niroshan Siriwardena, John Long, Gareth Clegg, Steven C. Brooks, Tim Chan, Steve Irving, Larry Walker, Craig Mortimer, Sandra Igbodo, Gavin D. Perkins

Notice bibliographique

RevueHealth and Social Care Delivery Research · 2025
Typearticle
Langueen
DomaineMedicine
ThématiqueCardiac Arrest and Resuscitation
Établissements canadiensQueen's UniversityUniversity of Toronto
Organismes subventionnairesHealth and Social Care Delivery ResearchDepartment of Health and Social CareHealth Services and Delivery Research ProgrammeNational Institute for Health and Care Research
Mots-clésAutomated external defibrillatorDefibrillationSoftware deploymentMedicineMedical emergencyBasic life supportEmergency medical servicesEmergency medicineReturn of spontaneous circulationCardiopulmonary resuscitationResuscitationComputer scienceInternal medicine

Résumé

récupéré en direct d'OpenAlex

Background: Ambulance services treat over 32,000 patients sustaining an out-of-hospital cardiac arrest annually, receiving over 90,000 calls. The definitive treatment for out-of-hospital cardiac arrest is defibrillation. Prompt treatment with an automated external defibrillator can improve survival significantly. However, their location in the community limits opportunity for their use. There is a requirement to identify the optimal location for an automated external defibrillator to improve out-of-hospital cardiac arrest coverage, to improve the chances of survival. Methods: This was a secondary analysis of data collected by the Out-of-Hospital Cardiac Arrest Outcomes registry on historical out-of-hospital cardiac arrests, data held on the location of automated external defibrillators registered with ambulance services, and locations of points of interest. Walking distance was calculated between out-of-hospital cardiac arrests, registered automated external defibrillators and points of interest designated as potential sites for an automated external defibrillator. An out-of-hospital cardiac arrest was deemed to be covered if it occurred within 500 m of a registered automated external defibrillator or points of interest. For the optimisation analysis, mathematical models focused on the maximal covering location problem were adapted. A de novo decision-analytic model was developed for the cost-effectiveness analysis and used as a vehicle for assessing the costs and benefits (in terms of quality-adjusted life-years) of deployment strategies. A meeting of stakeholders was held to discuss and review the results of the study. Results: grids and placing an automated external defibrillator in the centre increased coverage significantly to 78.8%. The optimisation model showed that if automated external defibrillators were placed in each points-of-interest location out-of-hospital cardiac arrest coverage levels would improve above the current situation significantly, but it would not reach that of optimisation-based placement (based on grids). The coverage efficiency provided by the optimised grid points was unmatched by any points of interest in any region. An economic evaluation determined that all alternative placements were associated with higher quality-adjusted life-years and costs compared to current placement, resulting in incremental cost-effectiveness ratios over £30,000 per additional quality-adjusted life-year. The most appealing strategy was automated external defibrillator placement in halls and community centres, resulting in an additional 0.007 quality-adjusted life-year (non-parametric 95% confidence interval 0.004 to 0.011), an additional expected cost of £223 (non-parametric 95% confidence interval £148 to £330) and an incremental cost-effectiveness ratio of £32,418 per quality-adjusted life-year. The stakeholder meeting agreed that the current distribution of registered publicly accessible automated external defibrillators was suboptimal, and that there was a disparity in their location in respect of deprivation and other health inequalities. Conclusions: We have developed a data-driven framework to support decisions about public-access automated external defibrillator locations, using optimisation and statistical models. Optimising automated external defibrillator locations can result in substantial improvement in coverage. Comparison between placement based on points of interest and current placement showed that the former improves coverage but is associated with higher costs and incremental cost-effectiveness ratio values over £30,000 per additional quality-adjusted life-year. Study registration: This study is registered as researchregistry5121. Funding: This award was funded by the National Institute for Health and Care Research (NIHR) Health and Social Care Delivery Research programme (NIHR award ref: NIHR127368) and is published in full in Health and Social Care Delivery Research; Vol. 13, No. 5. See the NIHR Funding and Awards website for further award information.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction machine sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.

score de la tête « metaresearch » (Codex)0,002
score de la tête « metaresearch » (Gemma)0,011
Version: metacan-v3-hybrid-931329e0061cStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Simulation ou modélisation · Signal consensuel: Simulation ou modélisation
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,101
Score d'incertitude au seuil0,201

Scores du classifieur distillé par catégorie (deux têtes)

CatégorieCodexGemma
Métarecherche0,0020,011
Méta-épidémiologie (sens strict)0,0010,001
Méta-épidémiologie (sens large)0,0010,001
Bibliométrie0,0010,001
Études des sciences et des technologies0,0000,001
Communication savante0,0020,001
Science ouverte0,0010,002
Intégrité de la recherche0,0010,001
Charge utile insuffisante (le modèle a refusé de juger)0,0030,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,053
Tête enseignante GPT0,397
Écart entre enseignants0,344 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeSimulation ou modélisation
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations2
Publié2025
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueHealth and Social Care Delivery ResearchMême sujetCardiac Arrest and ResuscitationTravaux en français237 207