Abstract During rapid load increase and decrease in circulating fluidized bed (CFB) units, the presence of a large amount of bed material, including incompletely combusted carbon residue and incompletely reacted calcium‐based desulphurizers, affects both the load change rate and pollutant emissions of the boiler. Therefore, the rational utilization of active stock within the boiler plays an important role in improving the heat release rate and increasing the load response rate. Using a 350 MW supercritical CFB boiler as the research object, numerical simulations were conducted on the load increase and decrease processes of the CFB boiler. Dynamic models of active carbon residue stock and active limestone were constructed to analyze the active stock during load increase and decrease processes. The results show that during the load increase from 175 to 350 MW, the coal feed rate is the main factor affecting the active carbon residue stock. The combustion rate of active carbon residue is lower than the coal feed rate, resulting in an increasing trend in active carbon residue stock, ranging from 6801.51 to 17,491.03 kg. During the load decrease from 350 to 300 MW, the active carbon residue stock decreases sharply, from 15,883.58 to 11,188.43 kg. During the load increase, there is a negative correlation between SO 2 concentration and active limestone stock. As the load increases from 208 to 280 MW, the SO 2 concentration rises from 1978.96 to 4951.94 mg/m 3 , while the active limestone stock decreases from 2223.65 to 1675.40 kg.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,001 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».