MétaCan
Menu
Retour à la cohorte
Enregistrement W4408845451 · doi:10.1007/s40123-025-01126-x

Six-Month Outcomes from a Prospective, Randomized Study of iStent infinite Versus Hydrus in Open-Angle Glaucoma: The INTEGRITY Study

2025· article· en· W4408845451 sur OpenAlexaff
Iqbal Ike K. Ahmed, John P. Berdahl, Arkadiy Yadgarov, George R. Reiss, Steven R. Sarkisian, Sébastien Gagné, Marco Robles, Lilit Voskanyan, Omar Sadruddin, Dari Parizadeh, Jane Ellen Giamporcaro, Angela C. Kothe, L. Jay Katz, Tomas Navratil

Notice bibliographique

RevueOphthalmology and Therapy · 2025
Typearticle
Langueen
DomaineMedicine
ThématiqueGlaucoma and retinal disorders
Établissements canadiensCentre Intégré de Santé et de Services Sociaux des LaurentidesPrism Eye Institute
Organismes subventionnairesnon disponible
Mots-clésMedicineGlaucomaIntraocular pressureOphthalmologyRandomized controlled trialAdverse effectGonioscopyProspective cohort studyOpen angle glaucomaGlaucoma surgerySurgeryInternal medicine

Résumé

récupéré en direct d'OpenAlex

INTRODUCTION: This was a prospective, randomized, double-masked, multicenter, 24-month study to compare effectiveness and safety outcomes following standalone implantation of two types of current generation trabecular stents in adults with open-angle glaucoma (OAG). An interim analysis was performed at month 6. METHODS: Eyes with OAG, mean IOP ≤ 24 mmHg on zero to three intraocular pressure (IOP)-lowering medications at screening, and with baseline mean diurnal IOP (MDIOP) 21-36 mmHg after medication washout were randomized to standalone implantation of the current generation of three trabecular micro-bypass stents (iStent infinite) or one trabecular bypass stent (Hydrus). Eyes on medication were to undergo a medication washout prior to the month 6 visit. Analyses included a comparison of the proportion of iStent infinite versus Hydrus eyes achieving MDIOP reduction of 20% or greater from baseline at month 6. Reduction from baseline in MDIOP and number of medications were also assessed. Safety parameters included intraoperative/postoperative complications, corrected visual acuity, slit-lamp biomicroscopy, ophthalmoscopy, gonioscopy, perimetry, and adverse events. RESULTS: Eyes with primarily mild-to-moderate disease severity were randomized: 91 iStent infinite eyes had screening mean (± standard deviation [SD]) IOP of 17.0 ± 3.2 mmHg on 1.6 ± 0.9 medications and baseline unmedicated MDIOP of 23.7 ± 2.9 mmHg; 89 Hydrus eyes had screening mean (± SD) IOP of 17.1 ± 3.3 mmHg on 1.5 ± 0.9 medications and baseline unmedicated MDIOP of 23.5 ± 2.7 mmHg. At month 6, a similar proportion of iStent infinite eyes (82.7%) versus Hydrus eyes (78.9%) achieved MDIOP reduction ≥ 20% from baseline regardless of IOP medication use or surgical complications. The difference was statistically significantly different (78.2% iStent infinite versus 65.0% Hydrus) for unmedicated MDIOP reduction ≥ 20% from baseline in eyes with no surgical complications (difference 13.2%; 95% confidence interval (CI) 3.0%, 23.3%). Mean MDIOP change from baseline, regardless of IOP medication use or surgical complications, was similar between groups (- 7.4 ± 2.9 mmHg iStent infinite and - 7.2 ± 2.9 mmHg Hydrus), whereas unmedicated MDIOP change from baseline without surgical complications was statistically significantly superior in iStent infinite eyes (- 6.8 ± 4.1 mmHg) versus Hydrus eyes (- 5.7 ± 4.1 mmHg) (difference - 1.1 mmHg; 95% CI - 2.0 mmHg, - 0.2 mmHg). Improper stent placement was reported in one iStent infinite and seven Hydrus eyes (1.1% versus 7.9%). One iStent infinite versus four Hydrus eyes experienced peripheral anterior synechiae > 1 mm (1.1% versus 4.5%). Overall, there were significantly fewer surgical complications in the iStent infinite eyes (3.3%) compared to Hydrus eyes (16.9%; difference of - 13.6%, 95% CI - 23.8%, - 3.4%). CONCLUSIONS: In this study of standalone implantation of current trabecular stent technologies in subjects with OAG, high proportions in both groups achieved clinically meaningful IOP reduction. When considering surgical complications as failures, a statistically significantly greater proportion of iStent infinite eyes versus Hydrus eyes had no surgical complications and achieved an unmedicated MDIOP reduction of ≥ 20%. The iStent infinite group also had clinically relevant and statistically significantly superior reduction from baseline in unmedicated MDIOP without surgical complications compared to Hydrus. TRIAL REGISTRATION: ClinicalTrials.gov identifier, NCT05127551.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,001
score de la tête « metaresearch » (Gemma)0,000
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Observationnel · Signal consensuel: Observationnel
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,111
Score d'incertitude au seuil0,960

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0010,000
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0010,000
Bibliométrie0,0000,000
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,036
Tête enseignante GPT0,347
Écart entre enseignants0,311 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeObservationnel
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations9
Publié2025
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueOphthalmology and TherapyMême sujetGlaucoma and retinal disordersTravaux en français237 207