Towards sustainable energy use: Reinforcement learning for demand response in commercial buildings
Notice bibliographique
Résumé
Demand response (DR) is a crucial strategy for balancing electricity demand and reducing environmental impact, especially as power consumption continues to rise. Small and medium-sized commercial buildings hold significant potential for DR implementation due to their widespread presence and substantial contribution to overall energy use. This study proposes a novel framework to optimize energy management in these buildings by considering three types of loads: non-controllable, controllable with discrete action spaces (HVAC), and controllable with continuous action spaces (lighting). The objective is to minimize costs, reduce CO 2 emissions, improve occupant comfort, and shave peak loads as a unified goal. State-of-the-art reinforcement learning (RL) algorithms are employed and compared against traditional heuristic methods using real-world data. Results show that RL-based approaches can significantly lower energy costs and environmental impacts while maintaining occupant comfort, even under varying outdoor temperature conditions. By incorporating risk assessments through Value at Risk (VaR) and Conditional Value at Risk (CVaR) metrics, this study offers a robust solution for sustainable energy management, providing insights for policymakers and industry practitioners aiming for a more resilient energy future.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,001 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».