Performance of full-scale 3D-printed concrete walls: Effects of vertical reinforcements and window opening
Notice bibliographique
Résumé
The 3D concrete printing is an advancing construction technology with the potential to revolutionize the building industry. This study investigates the structural performance of large-scale 3D-printed walls made with regular concrete containing coarse aggregates. The objectives of this study are to investigate important gaps related to the structural behavior of full-scale loadbearing walls, including the effects of a large window opening and vertical reinforcement. The methodology involved conducting full-scale compression load tests on wall specimens, printed and cured on-site under real-world conditions. These wall specimens included configurations with and without window openings, as well as reinforced and unreinforced walls. Key findings indicate that 3D-printed concrete walls with vertical reinforcement achieved up to a 26 % increase in loadbearing capacity and exhibited energy absorption up to three times greater than unreinforced walls. This study also found that the wall with a large window opening reached approximately 80 % of the loadbearing capacity of the specimen without an opening. The implications of this study provide novel knowledge about the performance of large 3D-printed concrete walls under compressive loads. This information will help in establishing guidelines for 3D printing in construction and building design codes.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».