MétaCan
Menu
Retour à la cohorte
Enregistrement W4411962233 · doi:10.1016/j.landig.2025.100886

Development of machine learning prediction models for systemic inflammatory response following controlled exposure to a live attenuated influenza vaccine in healthy adults using multimodal wearable biosensors in Canada: a single-centre, prospective controlled trial

2025· article· en· W4411962233 sur OpenAlexafffundabout
Amir Hadid, Emily G. McDonald, Qianggang Ding, Christopher Phillipp, Audrey Trottier, Philippe C. Dixon, Oussama Jlassi, Matthew P. Cheng, Jesse Papenburg, Michael Libman, Dennis Jensen

Notice bibliographique

RevueThe Lancet Digital Health · 2025
Typearticle
Langueen
DomaineMedicine
ThématiqueRespiratory viral infections research
Établissements canadiensMontreal Children's HospitalUniversité de MontréalMcGill University Health CentreMcGill University
Organismes subventionnairesCanadian Institutes of Health ResearchMcGill University Health CentreCanada Research ChairsMcGill University
Mots-clésMedicineAsymptomaticProspective cohort studySubclinical infectionBiomarkerImmunologyInternal medicineBiology

Résumé

récupéré en direct d'OpenAlex

BACKGROUND: Presymptomatic or asymptomatic immune system signals and subclinical physiological changes might provide a more objective measure of early viral upper respiratory tract infections (VRTIs) compared with symptom-based detection. We aimed to use multimodal wearable sensors, host-response biomarkers, and machine learning to predict systemic inflammation following controlled exposure to a live attenuated influenza vaccine, without relying on symptoms. METHODS: WE SENSE study is a single-centre (McGill University Health Center, Montreal, QC, Canada), prospective controlled trial that recruited healthy adults aged 18-59 years who had not received or were not planning to receive the seasonal influenza vaccine or any other vaccine during the study period. We excluded participants with any infectious symptoms within 7 days before screening. We collected physiological and activity data (eg, heart rate, breathing rate, and acceleration) through continuous monitoring with a smart ring (Oura ring Gen 2, Oura Oy, Finland), smart watch (Biobeat watch, Biobeat Technologies, Israel), and smart shirt (Astroskin-Hexoskin shirt, Hexoskin, Canada) along with high temporal resolution systemic inflammatory biomarker mapping over 12 days (7 days before inoculation and 5 days after). We frequently tested participants both before and after inoculation via PCR for respiratory pathogens, and monitored them via apps for symptoms and free-text annotations. Machine learning algorithms predicting systemic inflammatory surges were trained (35 participants), validated (ten participants), and tested (ten participants) using gradient-boosting techniques. FINDINGS: Between Dec 10, 2021, and Feb, 28, 2022, we enrolled 56 participants, of whom 55 had available data; all 55 participants continuously wore the Oura ring, 54 participants wore the Astroskin-Hexoskin shirt, and 50 wore the Biobeat watch. 27 (49%) participants were female and 28 (51%) were male; 31 (56%) participants were White, eight (15%) were Asian, four (7%) were Black, two (4%) were Latino or Hispanic, and ten (18%) did not disclose. We used model 2, which included handpicked features from the Oura ring night-time data, as the candidate model because it was built on the lowest number of features (more practical). This model predicted inflammatory surges with receiver operating characteristic area under the curve (ROC-AUC) of 0·73 (95% CI 0·71-0·74) for real-time prediction and 0·89 (0·87-0·90) for a 24-h tolerance prediction window (24h-tol) using night-time data from the Oura ring. Incorporating both night-time and daytime data from the Astroskin-Hexoskin shirt yielded ROC-AUC values of 0·73 (0·71-0·75) for real-time and 0·91 (0·90-0·92) for 24h-tol along with improved precision (ie, specificity [0·83, 0·79-0·87] and F1 score [0·65, 0·58-0·71]). The model based on symptoms alone had lower performance, with ROC-AUC values of 0·66 (0·63-0·68) for real-time and 0·79 (0·77-0·82) for 24h-tol. INTERPRETATION: Systemic inflammatory biomarkers coupled with physiological data from wearable biosensors provided rich and objective data from which to train machine learning algorithms to predict systemic inflammation from a low-grade influenza challenge. This approach outperformed symptom-based detection and has the potential to improve detection of VRTIs such as influenza and decrease time to detection, even among asymptomatic people. FUNDING: The Canadian Institutes of Health Research.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,003
score de la tête « metaresearch » (Gemma)0,003
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Essai randomisé · Signal consensuel: Essai randomisé
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,179
Score d'incertitude au seuil0,999

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0030,003
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0020,000
Bibliométrie0,0010,001
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,001
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,046
Tête enseignante GPT0,335
Écart entre enseignants0,289 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeEssai randomisé
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations13
Publié2025
Routes d'admission3
Résumé présentoui

Explorer davantage

Même revueThe Lancet Digital HealthMême sujetRespiratory viral infections researchTravaux en français237 207