S-values for bone marrow dosimetry in preclinical radiopharmaceutical studies with rodents
Pourquoi ce travail est dans la base
Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.
Notice bibliographique
Résumé
Abstract Background Development of novel radiopharmaceuticals involves dosimetry calculations to validate safety and aid with selection of those that should be translated into the clinical environment. Dosimetry is critical for limiting radiation damage to organs at risk. The bone marrow is a limiting organ in radiopharmaceutical therapies (RPTs) for metastatic prostate cancer, for example, but there is room for improvement of bone marrow dosimetry in preclinical studies. Bone marrow S -values for Lutetium-177 ( 177 Lu) in rodents have been published but they have not included tumor xenografts inoculated in the shoulder, which is how radiopharmaceuticals are often tested. Here, we aim at performing Monte Carlo simulations on digital mice phantoms including tumor xenografts, and to determine new bone marrow S-values that can potentially improve our understanding of the effect of RPTs in blood cells. Methods S -values for 177 Lu were simulated in the 4D Mouse Whole Body (MOBY) phantom, a hybrid voxel-based mouse model, using GATE v9.3 MC toolkit. Two phantoms of different resolutions and equal mass were created. 3D dose distributions were simulated and the corresponding organ to organ S -values were calculated. The resulting S -values were validated against reference values from OLINDA v2.2.3. Later, tumours of varying sizes were placed in the left shoulder and tumour-to-organ S -values were calculated from MC simulations with a 177 Lu source placed uniformly in these tumours. Results The phantoms simulated here differed from the OLINDA phantom in both organ mass and geometry for many tissues; S -value deviations from OLINDA were correlated with these differences, as reported in previous studies, and ranged from 2% for the kidney self-dose in the higher resolution (HR) phantom to 477% for S (skeleton←spleen) in the lower resolution (LR) phantom. S -values were simulated for the bone marrow in both phantoms; cross-dose values were greatest from the skeleton, brain, and lungs, while cross-doses from the simulated tumours were approximately constant at 3 × 10 –15 Gy Bq −1 s −1 across all tumour sizes. The components of the skeleton receiving the greatest tumour cross-doses from the tumours were the spine, skull and marrow. S -values targeting the bone marrow were compared to similar values from a previous study, whose phantom differed in tissue composition—discrepancies ranged from 6% for S(BM←kidneys) at LR to 87% for S (BM←BM) at HR. In general, relative uncertainty in dose and dose factor deposited from one tissue to another was inversely proportional to the corresponding S -value magnitude, and lower uncertainties were yielded from simulations in the LR, large-voxel phantom. Conclusion Using the MOBY digital mouse phantom, we simulated bone marrow S -values for 177 Lu. We hope these values help researchers perform preclinical dosimetry in rodents including bone marrow and tumor xenografts and facilitate the translation of novel radiopharmaceuticals.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle