Integrating a Multimodal Digital Device for Continuous Perioperative Monitoring in Patients With Lung Cancer Undergoing Thoracic Surgery: Development and Usability Study
Notice bibliographique
Résumé
BACKGROUND: Minimally invasive thoracic surgery has improved lung cancer outcomes but requires enhanced postoperative care. Traditionally, the episodic care model has limited timely and multidimensional monitoring of patients. Recent technological advances in multimodal digital devices, including wearable devices and electronic patient-reported outcomes (ePROs), offer a promising solution to these challenges. However, current studies focus on only a few parameters and limited application in thoracic surgery. OBJECTIVE: This study aims to propose a self-controlled study to evaluate the feasibility and reliability of multimodal digital devices, including wearables and ePROs, for continuous perioperative monitoring to enhance recovery after thoracic surgery. METHODS: We included 288 patients with non-small cell lung cancer from the Guangzhou Medical University cohort, which includes 2757 participants with various lung diseases. Digital data were collected during hospitalization using a commercial smartwatch combined with an ePROs questionnaire, while clinical data were obtained from electronic health records (EHRs). Agreement between the digital device and EHR was evaluated via Bland-Altman analysis. Time-series data were normalized for continuous outlier monitoring, and threshold analysis of ePROs scores were used to explore associations across different modules. RESULTS: Throughout hospitalization, digital devices provided a subjective overview of the patients' recovery trajectories. Results of Bland-Altman analysis demonstrated a high level of agreement between the digital device and the EHR. For body temperature, the analysis revealed a minimal bias of 0.02 °C (95% CI -0.01 °C to 0.05 °C), the agreement for heart rate showed a bias of 0.26 beats per minute (bpm; 95% CI -0.49 bpm to 1.01 bpm), and the bias for oxygen saturation was -0.06% (95% CI -0.27% to 0.15%), indicating close alignment between the 2 measurement methods. Meanwhile, wearable devices demonstrate significant potential in outlier detection compared to the episodic care model, offering accurate and sensitive monitoring of outliers between traditional measurement intervals. Using a thresholding method, we found that wearable metrics were correlated with the severity of ePROs. CONCLUSIONS: These findings highlight the reliability and clinical potential of digital device-based multimodal systems within the enhanced recovery after surgery framework, offering a novel approach for continuous perioperative monitoring.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».