A Targeting Arm for Interlocking Screws Reduces Radiation Exposure: Results of a Prospective Randomized Controlled Trial
Notice bibliographique
Résumé
OBJECTIVES: To compare time, fluoroscopic utilization, and number of misses for placement of far interlocking screws in tibial and femoral nails using a targeting arm (Targeter) versus perfect circle technique (Control). METHODS: . DESIGN: Prospective randomized controlled trial. SETTING: Single-center, large, urban, level 1 trauma center. PATIENT SELECTION CRITERIA: Patients ≥18 years old with a tibia or femur fracture (AO/OTA 31A, 32, or 42) treated with an intramedullary nail from November 2022 to December 2023 were included. OUTCOME MEASURES AND COMPARISONS: The main outcome measures were number of fluoroscopy images taken and average time elapsed to place each far interlocking screw. The far interlocking screws were defined as the screws farthest from the insertion handle. Comparisons were made between the Targeter and Control cohorts in terms of number of fluoroscopy images taken and average time elapsed to place each far interlocking screw, and the number of misses. RESULTS: Thirty-one patients were randomized to Targeter and 31 to Control. There were no significant differences between the Targeter and Control cohorts in patient sex (58.6% vs. 54.5% women, P = 0.75), age (range (20-90 vs. 18-91, mean 52.7 vs. 54.2, P = 0.81), BMI (mean 25.9 vs. 26.2, P = 0.66), AO classification (13.8% vs. 36.4% 31 A, 37.9% vs. 21.2% 32, 48.2% vs. 42.4% 42, P = 0.20), or number of open fractures (13.8% vs. 7.1%, P = 0.67) between the 2 cohorts. For the Targeter group, fewer images were used than Controls for the first (15.0 vs. 22.5, P = 0.002), second (11.5 vs. 18.0, P = 0.006), and combined first and second (25.0 vs. 39.0, P = 0.001) screws. There was no difference between the Targeter and Control cohorts in the time it took to place the first (6.3 vs. 7.3 minutes, P = 0.31), second (5.8 vs. 6.2 minutes, P = 0.63), or combined first and second (11.9 vs. 13.7 minutes, P = 0.63) screws. In the Control cohort, there was 1 missed screw (1.4%, n = 69). In the Targeter cohort, there were 3 missed screws (5.4%, n = 56), a 4-fold increase that did not reach statistical significance ( P = 0.31). CONCLUSIONS: In this prospective randomized controlled trial, a targeting arm decreased the number of fluoroscopic images used for all far interlocking screws as compared with the perfect circle technique without a reduction in time. There was a trend toward increased misses in the Targeter cohort ( P = 0.31). Although the reduction in radiation exposure may have a cumulative beneficial effect during the course of a surgeon's career, the trend of increased misses with the Targeter should be taken into account. LEVEL OF EVIDENCE: Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,006 | 0,012 |
| Méta-épidémiologie (sens strict) | 0,002 | 0,001 |
| Méta-épidémiologie (sens large) | 0,005 | 0,005 |
| Bibliométrie | 0,001 | 0,001 |
| Études des sciences et des technologies | 0,001 | 0,001 |
| Communication savante | 0,002 | 0,002 |
| Science ouverte | 0,001 | 0,001 |
| Intégrité de la recherche | 0,003 | 0,002 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,006 | 0,001 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».