New standards in HER2-low testing: the CASI-01 comparative methods study
Notice bibliographique
Résumé
BACKGROUND: The introduction of Trastuzumab deruxtecan (T-Dxd) has exposed clinically significant limitations in accurately detecting HER2-low expression testing when using immunohistochemistry (IHC) assays originally developed to detect HER2 over-expression. While HER2 testing is widely used to determine T-Dxd eligibility, no HER2-low assay was ever validated against HER2 protein expression. METHODS: To address this pressing need, the Consortium for Analytic Standardization in Immunohistochemistry (CASI) conducted the CASI-01 study, involving 54 IHC laboratories across Europe and the U.S. The study aimed to identify optimal assay conditions for accurate HER2 testing, differentiating between HER2 overexpression (3+) for Trastuzumab eligibility and HER2-low expression (1+ or ultra-low) for T-Dxd eligibility. The conventional FDA-cleared HER2 assay ("predicate") was compared with higher-sensitivity assays using pathologist versus image analysis readouts. HER2 overexpression was validated against HER2 gene amplification via in situ hybridisation (ISH), while HER2-low accuracy was evaluated using newly introduced HER2 reference standards and a novel IHC parameter-dynamic range. FINDINGS: CASI-01 revealed variability in predicate HER2 assays, with detection thresholds ranging from 30,000 to 60,000 among laboratories. Despite this variability, these assays demonstrated high accuracy for identifying HER2 overexpression (3+), with 85.7% (18/21) sensitivity (95% confidence limits 63.66-96.95%) and 100% (49/49) specificity (95% confidence limits 92.75-100%), though sensitivity may have been limited by the use of older tissue specimens, with loss or reduced expression levels of the HER2 protein. However, these same assays exhibited poor dynamic range for detecting HER2-low scores. Enhanced analytic sensitivity of IHC assays combined with image analysis overcame this limitation with HER2-low scores, achieving a six-fold improvement (p = 0.0017). INTERPRETATION: IHC assays with detection thresholds in the range of 30,000-60,000 HER2 molecules per cell yield accurate results for determination of Trastuzumab eligibility (HER2 3+) but fail to demonstrate the dynamic range for accurate HER2-low scores. Enhanced analytic sensitivity of HER2 assays combined with image analysis addresses this critical gap in HER2-low testing. More generally, CASI-01 introduces pivotal advancements in precision medicine: (a) the importance of reporting IHC analytic sensitivity and ability to demonstrate an assay dynamic range, and (b) image analysis can surpass pathologist readout accuracy in specific clinical contexts. FUNDING: This work was supported by the National Cancer Institute of the National Institutes of Health under Award Number R44CA268484.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,004 | 0,002 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,003 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».