A-374 i-STAT hs-TnI: High sensitivity cardiac troponin at the point of care
Notice bibliographique
Résumé
Abstract Background The i-STAT hs-TnI cartridge, for use with the i-STAT 1 analyzer, is the first point-of-care, high-sensitivity troponin test to provide lab-quality results at the patient bedside in the United States. The i-STAT hs-TnI test provides precise and accurate cardiac troponin results between 2.9 ng/L and 1000.0 ng/L using whole blood or plasma specimens in approximately 15 minutes. It is demonstrated to be safe and effective to meet the needs of clinicians as a high sensitivity cardiac troponin test to aid in the diagnosis of myocardial infarction. Methods Analytical performance of the i-STAT hs-TnI test in the i-STAT hs-TnI cartridge with the i-STAT 1 analyzer was demonstrated through testing of multi-day precision, linearity, limit of blank (LoB), limit of detection (LoD), limit of quantitation (LoQ), precision in whole blood and plasma, high altitude performance, and evaluation of other factors affecting results (hematocrit insensitivity, potential interfering substances). Performance was also evaluated against the definition of a “high sensitivity” cardiac troponin test as recommended in the Fourth Universal Definition of Myocardial Infarction (Thygesen et al., Circulation 2018). Results Acceptance criteria were met for all analytical performance studies. In the multi-day precision study, the within-laboratory precision (excluding outliers) ranged from 3.30 %CV to 6.61 %CV for sample levels ranging from 11.59 ng/L to 786.65 ng/L. Linearity was demonstrated across the reportable range of the test. The LoB, LoD and LoQ (20 %CV) were established to be 0.78 ng/L, 1.61 ng/L and 2.90 ng/L, respectively, in whole blood, and 0.57 ng/L, 1.05 ng/L and 1.18 ng/L, respectively, in plasma. Within-site precision across both sample types was less than 0.778 ng/L for sample levels below 12.0 ng/L and less than 8.05 %CV for sample levels above 12.0 ng/L. The i-STAT hs-TnI test exhibited acceptable performance up to 10,000 ft above sea level and demonstrated insensitivity to hematocrit levels between 15 %PCV and 55 %PCV. Performance of the i-STAT hs-TnI test was demonstrated to meet the definition of a “high sensitivity” cardiac troponin test. A coefficient of variance of 10% was achieved at 6.88 ng/L and 3.70 ng/L in whole blood and plasma, respectively, which are each below the 99th percentile upper reference limits (URL’s) of 13 ng/L (female), 28 ng/L (male) and 21 ng/L (overall) established in a Reference Range clinical study. Furthermore, greater than 50% of female and greater than 50% of male whole blood and plasma specimens from the apparently healthy (normal) population were detected above the respective LoD value. Conclusion The analytical performance studies demonstrate that the i-STAT hs-TnI cartridge with the i-STAT 1 analyzer offers precise and accurate cardiac troponin test results for safe and effective use at the point of care. The performance of i-STAT hs-TnI test was also shown to meet the definition of a “high sensitivity” cardiac troponin test. The studies were funded by Abbott Laboratories.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,003 | 0,003 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,001 |
| Bibliométrie | 0,002 | 0,001 |
| Études des sciences et des technologies | 0,001 | 0,001 |
| Communication savante | 0,002 | 0,000 |
| Science ouverte | 0,001 | 0,001 |
| Intégrité de la recherche | 0,001 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,016 | 0,008 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».