MétaCan
Menu
Retour à la cohorte
Enregistrement W4414811679 · doi:10.48550/arxiv.2507.11326

Euclid preparation. Overview of Euclid infrared detector performance from ground tests

2025· preprint· en· W4414811679 sur OpenAlexaff
B. Kubik, R. Barbier, J. D. Clemens, S Ferriol, A. Secroun, G. Smadja, W. Gillard, N. Fourmanoit, A. Ealet, Simon Conseil, J. Zoubian, R. Kohley, L. Conversi, T. Maciaszek, H Cho, W. A. Holmes, M. Seiffert, Augustyn Waczynski, Stefanie Wachter, K. Jahnkę, F. Grupp, C. Bonoli, L. Corcione, S. Dusini, E. Medinaceli, R. Laureijs, Anne Bonnefoi, M. Carle, A. Costille, Franck Ducret, J.-L Gimenez, Laurent Martin, L. Caillat, L Valenziano, N. Auricchio, P Battaglia, A Derosa, R Farinelli, F Cogato, G Morgante, M. Trifoglio, V. Capobianco, S. Ligori, E. Borsato, C Sirignano, L. Stančo, S. Ventura, R. Toledo-Moreo, L Patrizii, Y. Copin, Richard Foltz, E Prieto, N. Aghanim, B Altieri, S. Andreon, C. Baccigalupi, Marco Baldi, A. Balestra, S Bardelli, Francis Bernardeau, A Biviano, E Branchini, M. Brescia, J. Brinchmann, S. Camera, G Cañas-Herrera, C. Carbone, J. Carretero, Santiago Casas, M. Castellano, G. Castignani, S Cavuoti, A. Cimatti, G. Congedo, F. Courbin, A da Silva, R da Silva, H. Degaudenzi, G de Lucia, H. Dole, M. Douspis, F. Dubath, X. Dupac, S. Escoffier, M. Farina, F Faustini, F Finelli, S. Fotopoulou, M. Frailis, E. Franceschi, M. Fumana, S. Galeotta, B Gillis, C. Giocoli, J. Gracia-Carpio, A Grazian, L. Guzzo, J. Hoar, H Hoekstra, F. Hormuth, A. Hornstrup, P. Hudelot, M Jhabvala, E. Keihänen, S. Kermiche, A. Kiessling, M Kümmel, M. Kunz, H. Kurki‐Suonio, P. Liebing, V. Lindholm, I. Lloro, G Mainetti, D. Maino, E Maiorano, O. Mansutti, S Marcin, O Marggraf, M. Martinelli, N. Martinet, F. Marulli, R. Massey, S. Maurogordato, S Mei, M Melchior, Y. Mellier, M. Meneghetti, E. Merlin, G. Meylan, A Mora, M. Moresco, L. Moscardini, R Nakajima, C. Neissner, S. Paltani, F. Pasian, K. Pedersen, V. Pettorino, S Pires, G. Polenta, M. Poncet, L. Pozzetti, F. Raison, R. Rébolo, A. Renzi, J. Rhodes, G. Riccio, E. Romelli, M. Roncarelli, E. Rossetti, R. P. Saglia, Z. Sakr, D. Sapone, B. Sartoris, M. Schirmer, P. C. Schneider, T. Schrabback, M. Scodeggio, E. Sefusatti, G. Seidel, S. Serrano, Pardis Simon, G Sirri, J. Steinwagner, P. Tallada-Crespí, D. Tavagnacco, I Tereno, Sune Toft, F. Torradeflot, A. Tsyganov, I. Tutusaus, J. Väliviita, T. Vassallo, G. Verdoes Kleijn, A Veropalumbo, Yun Wang, J. Weller, G Zamorani, E. Zucca, V. Allevato, M. Ballardini, M Bolzonella, E. Bozzo, C. Burigana, R. Cabanac, A. Cappi, P Casenove, D. Di Ferdinando, L. Gabarra, J Martín-Fleitas, S Matthew, N. Mauri, A Pezzotta, M. Pöntinen, C. Porciani, I Risso, V Scottez, M. Sereno, M. Tenti, M Viel, M. Wiesmann, Y. Akrami, S Anselmi, M. Archidiacono, F. Atrio‐Barandela, Daniele Bertacca, M. Béthermin, Alain Blanchard, L Blot, S Borgani, S Bruton, A Calabro, B. Camacho Quevedo, F Caro, T. Castro, Y Charles, Ranga‐Ram Chary, O Cucciati, S. Davini, F. De Paolis, G. Desprez, A. Díaz‐Sánchez, S. Di Domizio, Paola Dimauro, A Enia, A. Finoguenov, A. Fontana, A. Franco, K. Ganga, J. García-Bellido, T Gasparetto, V Gautard, E. Gaztañaga, F. Giacomini, F. Gianotti, G. Gozaliasl, M Guidi, A Hall, H Hildebrandt, J. Hjorth, Y. W. Kang, V. Kansal, D. Karagiannis, K Kiiveri, Sandor Kruk, L. Legrand, Maria Lembo, F Lepori, G Leroy, J. Lesgourgues, Laura Leuzzi, A. Loureiro, J. F. Macías–Pérez, G Maggio, M. Magliocchetti, C. Mancini, F. Mannucci, L. Maurin, M Miluzio, P Monaco, A Montoro, Chiara Moretti, Cherry A. Murray, S Nadathur, Krishna Naidoo, A Navarro-Alsina, F Passalacqua, K Paterson, A. Pisani, D. Potter, S Quai, M. Radovich, S Sacquegna, M Sahlén, E Sarpa, Aurel Schneider, D Sciotti, Elena Sellentin, G. Setnikar, K Tanidis, C. Tao, G. Testera, R Teyssier, S. Tosi, A Troja, M Tucci, C Valieri, A. Venhola, D. Vergani, G Verza, L. Zalesky

Notice bibliographique

RevueArXiv.org · 2025
Typepreprint
Langueen
DomaineEngineering
ThématiqueCalibration and Measurement Techniques
Établissements canadiensPerimeter InstituteUniversity of Waterloo
Organismes subventionnairesFundação para a Ciência e a TecnologiaNorsk RomsenterAgenția Spațială RomânăAgenzia Spaziale ItalianaMagyar Tudományos AkadémiaEuropean Space AgencyMinisterio de Ciencia, Innovación y UniversidadesNational Aeronautics and Space Administration
Mots-clésPixelDetectorNoise (video)Data acquisitionEstimatorFixed-pattern noiseInfrared detectorInfraredDynamic range

Résumé

récupéré en direct d'OpenAlex

The paper describes the objectives, design and findings of the pre-launch ground characterisation campaigns of the Euclid infrared detectors. The pixel properties, including baseline, bad pixels, quantum efficiency, inter pixel capacitance, quantum efficiency, dark current, readout noise, conversion gain, response nonlinearity, and image persistence were measured and characterised for each pixel. We describe in detail the test flow definition that allows us to derive the pixel properties and we present the data acquisition and data quality check software implemented for this purpose. We also outline the measurement protocols of all the pixel properties presented and we provide a comprehensive overview of the performance of the Euclid infrared detectors as derived after tuning the operating parameters of the detectors. The main conclusion of this work is that the performance of the infrared detectors Euclid meets the requirements. Pixels classified as non-functioning accounted for less than 0.2% of all science pixels. IPC coupling is minimal and crosstalk between adjacent pixels is less than 1% between adjacent pixels. 95% of the pixels show a QE greater than 80% across the entire spectral range of the Euclid mission. The conversion gain is approximately 0.52 ADU/e-, with a variation less than 1% between channels of the same detector. The reset noise is approximately equal to 23 ADU after reference pixels correction. The readout noise of a single frame is approximately 13 $e^-$ while the signal estimator noise is measured at 7 $e^-$ in photometric mode and 9 $e^-$ in spectroscopic acquisition mode. The deviation from linear response at signal levels up to 80 k$e^-$ is less than 5% for 95% of the pixels. Median persistence amplitudes are less than 0.3% of the signal, though persistence exhibits significant spatial variation and differences between detectors.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,000
score de la tête « metaresearch » (Gemma)0,000
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesMéta-épidémiologie (sens strict)
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Observationnel · Signal consensuel: Observationnel
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,185
Score d'incertitude au seuil1,000

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0000,000
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0000,000
Bibliométrie0,0000,000
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,001
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,081
Tête enseignante GPT0,298
Écart entre enseignants0,217 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Devis d'étudeObservationnel
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations0
Publié2025
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueArXiv.orgMême sujetCalibration and Measurement TechniquesTravaux en français237 207