A Directional Element for Inverter-Based Microgrids
Notice bibliographique
Résumé
Renewable energy sources integrated into the system via power electronic interfaces are becoming increasingly common in both power transmission and microgrids. These sources have different fault current characteristics compared to synchronous generators, primarily due to the current limit of the power electronic switches and the control systems of their power electronic interfaces. Due to the unique fault current characteristics of inverters, conventional directional elements might malfunction when inverter-based distributed energy resources are present in a microgrid. Therefore, this paper proposes a directional element to identify the current direction during fault. The proposed directional element determines the fault current direction by evaluating shifts in the current phase angle. In addition, a protection scheme is introduced to protect the microgrid against short circuit faults. The effectiveness of the proposed directional element and protection scheme are evaluated by the simulation of an inverter-based benchmark microgrid under different scenarios in MATLAB Simulink software. The performance of the proposed method is also experimentally validated and compared with directional overcurrent protection (ANSI code: 67) and voltage restrained overcurrent protection (51V) in controller hardware in the loop setup using an FPGA-based controller and physical relays.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,001 |
| Méta-épidémiologie (sens large) | 0,000 | 0,001 |
| Bibliométrie | 0,001 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».