MétaCan
Menu
Retour à la cohorte
Enregistrement W4416588311 · doi:10.2196/66931

Impact of AI on Breast Cancer Detection Rates in Mammography by Radiologists of Varying Experience Levels in Singapore: Preliminary Comparative Study

2025· article· en· W4416588311 sur OpenAlexvenueno aff
Serene Si Ning Goh, Hao Du, Loon Ying Tan, E. Seah, Wai Keat Lau, Alvin Hong Zhi Ng, Desmond Shi Wei Lim, Han Yang Ong, Samuel Lau, Yi Liang Tan, M.J. Khaw, Chee Woei Yap, Kei Yiu Douglas Hui, Wei Chuan Tan, Haziz Siti Rozana Binti Abdul, Vanessa Meihui Khoo, Shuliang Ge, Felicity Jane Pool, Yun Song Choo, Yi Wang, Pooja Jagmohan, Mikael Hartman, Mengling Feng

Notice bibliographique

RevueJMIR Formative Research · 2025
Typearticle
Langueen
DomaineComputer Science
ThématiqueAI in cancer detection
Établissements canadiensnon disponible
Organismes subventionnairesnon disponible
Mots-clésGeneralizability theoryMammographyBreast cancerBreast cancer screeningMammography screeningScreening mammography

Résumé

récupéré en direct d'OpenAlex

Background: Breast cancer remains the most common cancer among women globally. Mammography is a key diagnostic modality; however, interpretation is increasingly challenged by rising imaging volumes, a global shortage of breast radiologists, and variability in reader experience. Artificial intelligence (AI) has been proposed as a potential adjunct to address these issues, particularly in settings with high breast density, such as Asian populations. This study aimed to evaluate the impact of AI assistance on mammographic diagnostic performance among resident and consultant radiologists in Singapore. Objective: To assess whether AI assistance improves diagnostic accuracy in mammographic breast cancer detection across radiologists with varying levels of experience. Methods: A multi-reader, multi-case study was conducted at the National University Hospital, Singapore, from May to August 2023. De-identified digital mammograms from 500 women (250 with cancer and 250 normal or benign) were interpreted by 17 radiologists (4 consultants, 4 senior residents, and 9 junior residents). Each radiologist read all cases over 2 reading sessions: one without AI assistance and another with AI assistance, separated by a 1-month washout period. The AI system (FxMammo) provided heatmaps and malignancy risk scores to support decision-making. Area under the curve of the receiver operating characteristic (AUROC) was used to evaluate diagnostic performance. Results: Among the 500 cases, 250 were malignant and 250 were non-malignant. Of the malignant cases, 16%(80/500) were ductal carcinoma in situ and 84%(420/500) were invasive cancers. Among non-malignant cases, 69.2%(346/500) were normal, 17.6%(88) benign, and 3.6%(18/500) possibly benign but stable on follow-up. Masses (54.4%, 272) and calcifications (10.8%, 54/500) were the most common findings in cancer cases. A majority of both malignant (66.8%, 334/500) and non-malignant (68%, 340/500) cases had heterogeneously or extremely dense breasts (BIRADS [Breast Imaging Reporting and Data System] categories C and D). The AI model achieved an AUROC of 0.93 (95% CI 0.91-0.95), slightly higher than consultant radiologists (AUROC 0.90, 95% CI 0.89-0.92; P=.21). With AI assistance, AUROC improved among junior residents (from 0.84 to 0.86; P=.38) and senior residents (from 0.85 to 0.88; P=.13), with senior residents approaching consultant-level performance (AUROC difference 0.02; P=.051). Diagnostic gains with AI were greatest in women with dense breasts and among less experienced radiologists. AI also improved inter-reader agreement and time efficiency, particularly in benign or normal cases. Conclusions: This is the first study in Asia to evaluate AI assistance in mammography interpretation by radiologists of varying experience. AI significantly improved diagnostic performance and efficiency among residents, helping to narrow the experience-performance gap without compromising specificity. These findings suggest a role for AI in enhancing diagnostic consistency, improving workflow, and supporting training. Integration into clinical and educational settings may offer scalable benefits, though careful attention to threshold calibration, feedback loops, and real-world validation remains essential. Further studies in routine screening settings are needed to confirm generalizability and cost-effectiveness.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction machine sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.

score de la tête « metaresearch » (Codex)0,002
score de la tête « metaresearch » (Gemma)0,009
Version: metacan-v3-hybrid-931329e0061cStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Observationnel · Signal consensuel: Observationnel
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,006
Score d'incertitude au seuil0,012

Scores du classifieur distillé par catégorie (deux têtes)

CatégorieCodexGemma
Métarecherche0,0020,009
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0000,001
Bibliométrie0,0010,001
Études des sciences et des technologies0,0000,000
Communication savante0,0010,001
Science ouverte0,0000,001
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0010,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,079
Tête enseignante GPT0,474
Écart entre enseignants0,395 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeObservationnel
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations1
Publié2025
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueJMIR Formative ResearchMême sujetAI in cancer detectionTravaux en français237 207